This paper presents the feasibility of automated and accurate in vivo measurements of vascular parameters using an ultrasound sensor. The continuous and non-invasive monitoring of certain parameters, such as pulse wave velocity (PWV), blood pressure (BP), arterial compliance (AC), and stiffness index (SI), is crucial for assessing cardiovascular disorders during surgeries and follow-up procedures. Traditional methods, including cuff-based or invasive catheter techniques, serve as the gold standard for measuring BP, which is then manually used to calculate AC and SI through imaging algorithms. In this context, the Continuous and Non-Invasive Vascular Stiffness and Arterial Compliance Screener (CaNVAS) is developed to provide continuous and non-invasive measurements of these parameters using an ultrasound sensor. By driving 5 MHz (ranging from 2.2 to 10 MHz) acoustic waves through the arterial walls, capturing the reflected echoes, and employing pre-processing techniques, the frequency shift is utilized to calculate PWV. It is observed that PWV measured by CaNVAS correlates exponentially with BP values obtained from the sphygmomanometer (BPMR-120), enabling the computation of instantaneous BP values. The proposed device is validated through measurements conducted on 250 subjects under pre- and post-exercise conditions, demonstrating an accuracy of 95% and an average coefficient of variation of 12.5%. This validates the reliability and precision of CaNVAS in assessing vascular parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10452122PMC
http://dx.doi.org/10.3390/bios13080757DOI Listing

Publication Analysis

Top Keywords

vascular parameters
12
continuous non-invasive
12
parameters ultrasound
8
ultrasound sensor
8
arterial compliance
8
parameters
5
computation vascular
4
parameters implementing
4
implementing methodology
4
methodology performance
4

Similar Publications

Transient ischemic attack (TIA) is a well-established risk factor for future strokes, making interventions that target recovery and vascular risk crucial. This study aimed to assess the safety and clinical effects of a polyphenol-rich extract in post-TIA patients. A randomized, triple-blind, placebo-controlled trial was conducted with participants who had a history of TIA or minor stroke and who received 1 g of Salicornia extract or placebo over 11 months.

View Article and Find Full Text PDF

Study on the Abrasive Blasting Mechanism of Solder Welded 304V Wire in Vascular Intervention.

Micromachines (Basel)

November 2024

Department of Vascular Surgery, General Surgery Clinical Center, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, 100 Haining Road, Shanghai 200080, China.

The solder burrs on the 304V wire surface can easily scratch the vascular tissue during interventional treatment, resulting in complications such as medial tears, bleeding, dissection, and rupture. Abrasive blasting is often used to remove solder burr and obtain a smooth surface for the interventional device. This study conducted an abrasive blasting experiment to explore the effects of process parameters (air pressure, lift-off height, abrasive volume, and abrasive type) on processing time, surface roughness, and mechanical properties to reveal the material removal mechanism.

View Article and Find Full Text PDF

Severity-Dependent Long-Term Post-Traumatic Changes in the Circulating Oxylipin Profile.

Int J Mol Sci

December 2024

Research Laboratories and Clinic of Orthopedics, Trauma and Plastic Surgery, Leipzig University and University Hospital Leipzig, 04103 Leipzig, Germany.

Trauma causes the breakdown of membrane phospholipids and the subsequent degradation of the released polyunsaturated fatty acids (PUFAs) to partially bioactive oxylipins. Here, we screened for circulating PUFAs and oxylipins in patients (n = 34) differing from those of uninjured controls (n = 25) and analyzed their diagnostic potential. Patients were followed up for 1 to 240 h after minor/moderate, severe, and very severe injuries.

View Article and Find Full Text PDF

The present study aimed to investigate and compare oxidative stress biomarkers and antioxidant enzyme activity in the serum of women at risk of developing preeclampsia (PE) to prevent adverse pregnancy outcomes through early intervention. Changes in soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PlGF) levels were measured between 11 and 13 gestational weeks (gw.) before the onset of preeclampsia and its associated complications.

View Article and Find Full Text PDF

Medullary thyroid carcinoma (MTC), a rare neuroendocrine tumor comprising 3-5% of thyroid cancers, arises from calcitonin-producing parafollicular C cells. Despite aggressive behavior, surgery remains the primary curative treatment, with limited efficacy reported for radiotherapy and chemotherapy. Recent efforts have explored the pathogenetic mechanisms of MTC, identifying it as a highly vascularized neoplasm overexpressing pro-angiogenic factors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!