Background: Radial head fractures not amenable to reconstruction should be treated by radial head replacement (RHR) when there is associated elbow or forearm instability. There are multiple RHR designs with different philosophies, but 2 of the most commonly used implants include the anatomic press-fit radial head system and the loose-fit metallic spacer. There is little information available specifically comparing the long-term clinical and radiographic outcomes of these 2 systems. The objective of this study was to compare the long-term clinical and radiologic outcomes of 2 RHR designs in the context of complex acute elbow instability.

Materials And Methods: Ninety-five patients with an average age of 54 years (range, 21-87 years) underwent an acute RHR (46 press-fit Acumed anatomic and 49 loose-fit Evolve metallic spacer) and were prospectively followed for an average of 61 months (range, 24-157 months). There were 34 terrible triads; 36 isolated RH fractures with medial, lateral, or longitudinal instability; and 25 RH fractures associated with a proximal ulnar fracture. Clinical outcome and disability were evaluated with the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score, and the Disabilities of the Arm, Shoulder, and Hand (DASH) score. Pain and satisfaction were assessed using a visual analog scale. Radiographic analysis included presence of loosening, bone loss, and overstuffing related to the RHR.

Results: Eight patients with an anatomic RHR (2 with overstuffing, 3 for stiffness, and 3 with loose implants) and 1 patient with a spacer (with stiffness) required implant removal. There were no significant differences between spacer RHR and anatomic RHR in arc of motion (120° vs. 113°, P = .14), pain relief (1 vs. 1.7, P = .135), MEPS (94 vs. 88; P = .07), Oxford Elbow Score (42.3 vs. 42.2, P = .4), or DASH score (12.2 vs. 14.4, P = .5). However, patients with a spacer RHR were significantly more satisfied (9 vs. 7.7; P = .004) than those with an anatomic implant. Radiographically, 19 anatomic implants had significant proximal bone loss and 10 showed complete lucent lines around the stem. Lucent lines were common around the spacer RHR. These radiographic changes were not always related to worse clinical outcomes.

Conclusion: Both the anatomic and spacer RHR designs can provide good clinical long-term outcomes. However, patients with a spacer showed a higher degree of satisfaction and those with an anatomic press-fit RHR had a higher revision rate, with radiographic changes that warrant continued follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2023.07.023DOI Listing

Publication Analysis

Top Keywords

radial head
16
spacer rhr
16
rhr designs
12
rhr
11
head replacement
8
anatomic
8
anatomic press-fit
8
spacer
8
metallic spacer
8
long-term clinical
8

Similar Publications

Functional soft palate reconstruction.

JPRAS Open

March 2025

Department of Plastic, Reconstructive, Aesthetic, and Hand Surgery, University Hospital Basel, Basel, Switzerland.

Background: The excision of oropharyngeal carcinoma of more than 50% of the soft palate followed by static reconstruction may result in functional deficits, including velopharyngeal insufficiency, swallowing, and speech difficulties. We describe a functional soft palate reconstruction technique aimed at restoring aeromechanical and acoustic functions, enabling swallowing without nasal regurgitation and speech with low nasalance.

Material And Methods: We developed a new operative technique, using muscle transfer and a free flap to create a dynamic reconstruction.

View Article and Find Full Text PDF

The use of proteins as intracellular probes and therapeutic tools is often limited by poor intracellular delivery. One approach to enabling intracellular protein delivery is to transform proteins into spherical nucleic acid (proSNA) nanoconstructs, with surfaces chemically modified with a dense shell of radially oriented DNA that can engage with cell-surface receptors that facilitate endocytosis. However, proteins often have a limited number of available reactive surface residues for DNA conjugation such that the extent of DNA loading and cellular uptake is restricted.

View Article and Find Full Text PDF

Objective: Complex ablative maxillary and mandibular defects often require osseous free flap reconstruction. Workhorse options include the fibula, scapula, and osteocutaneous radial forearm flap (OCRFF). The choice of donor site for harvest should be driven not only by reconstructive goals but also by donor site morbidity.

View Article and Find Full Text PDF

Introduction: Osteochondroma is a bony lesion arising from the surface of the bone. It com-prises a large percentage of all benign bone tumors. A unique feature of this tumor is the conti-nuity of cortical and medullary components between the normal bony tissue and aberrant tissue of osteochondroma.

View Article and Find Full Text PDF

Trends in treatment and epidemiology of radial head fractures.

Shoulder Elbow

January 2025

Rothman Orthopaedics Florida at AdventHealth, Orlando, FL, USA.

Objective: We aimed to assess the recent trends in the demographics of radial head and neck fractures and their management based on displacement.

Methods: TriNetX was queried for cases from 1 January 2017, through 31 December 2022. ICD diagnosis codes were used to define patient cohorts with radial head or neck fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!