A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance and patients' satisfaction with the A7+TouchCare insulin patch pump system: A randomized controlled non-inferiority study. | LitMetric

Background: We assessed the performance and patient satisfaction of a new insulin patch pump, the A7+TouchCare (Medtrum), compared with the Omnipod system.

Methods: This multicenter, randomized, open-label, controlled study enrolled 100 adult patients with type 1 or type 2 diabetes mellitus (A1C ≥ 6.5% and ≤ 9.5%, i.e., 48 to 80 mmol/mol) who were assigned with the Omnipod or with the A7+TouchCare pump for 3 months. The primary study outcome was the glucose management indicator (GMI) calculated with continuous glucose monitoring (CGM).

Results: Premature withdrawals occurs respectively in 2 and 9 participants in the Omnipod and TouchCare groups. In the Per Protocol analysis, the difference in GMI between groups was 0.002% (95% confidence interval -0.251; 0.255). The non-inferiority was demonstrated since the difference between treatments did not overlap the pre-defined non-inferiority margin (0.4%). There was no significant difference in CGM parameters between groups. On average, patients in both groups were satisfied/very satisfied with the insulin pump system. Patients preferred Omnipod as an insulin management system and especially the patch delivery system but preferred the A7+TouchCare personal diabetes manager to control the system.

Conclusions: This study showed that the A7+TouchCare insulin pump was as efficient as the Omnipod pump in terms of performance and satisfaction.

Clinical Trail Registration: The study was registered in the ClinicalTrials.gov protocol register (NCT04223973).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10449223PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0289684PLOS

Publication Analysis

Top Keywords

a7+touchcare insulin
8
insulin patch
8
patch pump
8
pump system
8
insulin pump
8
pump
6
a7+touchcare
5
insulin
5
study
5
omnipod
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!