Associate Professor, Serra Hunter Fellow, Department of Odontostomatology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Catalonia, Spain; and Researcher, Oral Health and Masticatory System Group (Bellvitge Biomedical Research Institute) IDIBELL, L'Hospitalet de Llobregat, Barcelona, Catalonia, Spain. Electronic address:

Published: July 2024

Statement Of Problem: The accuracy of methods used for locating occlusal contacts throughout the entire clinical procedure has been poorly studied.

Purpose: The purpose of this clinical study was to determine the reproducibility and criterion validity for different methods of locating occlusal contacts.

Material And Methods: Thirty-two adults with natural dentitions participated in this cross-sectional test-retest study. In total, occlusal contacts at maximum intercuspation were recorded by using 15 methods: silicone transillumination with Occlufast Rock (40, 50, 100, and 200 µm) and Occlufast CAD (40 and 50 µm); virtual occlusion (100, 200, 300, and 400 µm); articulating film (12-, 40-, 100-, and 200-µm-thick); and T-Scan III. Images of the occlusal records were scaled and calibrated spatially, and the occlusal contacts of the right posterior mandibular teeth were delimited by using the FIJI software program. Reproducibility was expressed as 95% confidence intervals (95% CI) of the percentage of agreement in the location of the occlusal contacts between images from the test sessions against retest sessions using the same method. Criterion validity was expressed as 95% CI of the percentage of agreement in the location of the occlusal contacts between images from the test sessions against images from Occlufast Rock (criterion standard).

Results: Occlufast Rock achieved 85% to 95% agreement in the location of the occlusal contacts between the 2 sessions, whereas Occlufast CAD, 200-µm articulating film, and T-Scan offered 79% to 86%, 68% to 75%, and 65% to 75% agreement, respectively. The most valid method was Occlufast CAD (74% to 80%) followed by the 200-µm articulating film (57% to 63%), 400-µm virtual occlusion (53% to 62%), 100-µm articulating film (52% to 60%), and T-Scan (48% to 56%).

Conclusions: Conventional methods, such as 100- and 200-µm articulating film and digital methods, including 400 µm virtual occlusion and T-Scan, offer sufficient accuracy in locating the occlusal contacts. However, strategies are needed to improve accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2023.06.036DOI Listing

Publication Analysis

Top Keywords

occlusal contacts
32
articulating film
20
locating occlusal
16
occlufast rock
12
occlufast cad
12
virtual occlusion
12
agreement location
12
location occlusal
12
200-µm articulating
12
occlusal
10

Similar Publications

Aims: To verify the possible association between the stomatognathic and the visual system by analyzing the effects that different mandibular postures may have on the accommodative capacity and ocular convergence and by assessing whether temporomandibular disorders (TMD) can influence visual abilities.

Materials And Methods: A case-control study was performed during a 1-year period on a sample of 100 subjects (50 cases and 50 controls). The subjects underwent a gnathological examination, and two visual tests were performed in three different jaw positions: maximum intercuspation, resting position, and open mouth.

View Article and Find Full Text PDF

Objective: To measure and analyze the occlusal force and contact in children with mixed dentition, and to preliminarily provide baseline data on the occlusion of individual normal occlusion children with mixed dentition.

Methods: A cross-sectional study was conducted, including 20 children with mixed dentition and individual normal occlusion, consisting of 12 boys and 8 girls, aged 6.5-9.

View Article and Find Full Text PDF

Objective: To evaluate the clinical efficacy of clear aligner therapy in patients with severe periodontitis accompanied by pathological tooth displacement in the anterior region.

Methods: This retrospective study analyzed patients diagnosed with severe periodontitis and pathological displacement in the anterior region, who visited both the Periodontics and Orthodontics Departments at Peking University School and Hospital of Stomatology between 2019 and 2022. A total of 26 eligible cases were included in this study.

View Article and Find Full Text PDF

To observe the stability of vertical dimension of occlusion (VDO) and mandibular position in full-mouth occlusal reconstruction subjects by means of digital occlusal analysis. Six subjects who had completed full-mouth occlusal reconstruction by intraoral functional generated path technique for more than three years in the Department of Prosthodontics, Peking University School and Hospital of Stomatology were enrolled for follow-up observation, all six patients were male, with an age of (53.6±8.

View Article and Find Full Text PDF

A cross-sectional study on improving clinical efficiency through centralized digital impression.

Hua Xi Kou Qiang Yi Xue Za Zhi

February 2025

Center of Stomatology, Peking University Shenzhen Hospital, Shenzhen 518036, China.

Objectives: This study aims to explore the effect of improving clinical efficiency by replacing traditional impression workflow with centralized digital impression workflow.

Methods: The department of prosthodontics in Center of Stomatology, Peking University Shenzhen Hospital has improved the clinical workflow by replacing the traditional impression made by doctors using impression materials for each patient with a centralized digital impression made by one technician for all patients in the department. This cross-sectional study recorded the chairside time required for impression taking in patients undergoing single posterior zirconia full crown restoration before clinical process improvement; the time required for centralized digital impression production; the comfort level of patients; and the adjacency relationship, occlusal contact relationship, and time required for prostheses adjusting (i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!