A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mapping Heterogeneity of Pristine and Aged Li- and Na-Mnhcf Cathode by Synchrotron-Based Energy-Dependent Full Field Transmission X-ray Microscopy. | LitMetric

AI Article Synopsis

  • Manganese hexacyanoferrate shows potential as a cathode material for lithium and sodium ion batteries but experiences capacity loss during cycling.
  • Researchers used transmission soft X-ray microscopy to analyze fresh and cycled electrodes at a nanometer scale, focusing on elements like manganese, iron, and nitrogen.
  • Findings revealed increased structural inhomogeneities in aged electrodes, especially in lithium-ion batteries, indicating that redox coupling and electron delocalization may affect performance and cycle life.

Article Abstract

Manganese hexacyanoferrate is a promising cathode material for lithium and sodium ion batteries, however, it suffers of capacity fading during the cycling process. To access the structural and functional characteristics at the nanometer scale, fresh and cycled electrodes are extracted and investigated by transmission soft X-ray microscopy, which allows chemical characterization with spatial resolution from position-dependent x-ray spectra at the Mn L-, Fe L- and N K-edges. Furthermore, soft X-rays prove to show superior sensitivity toward Fe, compare to hard X-rays. Inhomogeneities within the samples are identified, increasing in the aged electrodes, more dramatically in the Li-ion system, which explains the poorer cycle life as Li-ion cathode material. Local spectra, revealing different oxidation states over the sample with strong correlation between the Fe L-edge, Mn L-edge, and N K-edge, imply a coupling between redox centers and an electron delocalization over the host framework.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smtd.202300718DOI Listing

Publication Analysis

Top Keywords

x-ray microscopy
8
cathode material
8
mapping heterogeneity
4
heterogeneity pristine
4
pristine aged
4
aged li-
4
li- na-mnhcf
4
na-mnhcf cathode
4
cathode synchrotron-based
4
synchrotron-based energy-dependent
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!