Background: Sodium zirconium cyclosilicate, a non-absorbed non-polymer zirconium silicate, is a new potassium binder for hyperkalemia. A previous report showed that administering sodium zirconium cyclosilicate to patients with hyperkalemia allows a higher continuation rate of renin-angiotensin-aldosterone system inhibitors. However, no studies have compared sodium zirconium cyclosilicate with existing potassium binders for renin-angiotensin-aldosterone system inhibitor continuity. The purpose of this study was to evaluate the effect of sodium zirconium cyclosilicate on angiotensin-converting enzyme inhibitor /angiotensin receptor blocker continuation in patients with hyperkalemia compared to that of calcium polystyrene sulfonate.
Methods: Patients on angiotensin-converting enzyme inhibitors/angiotensin receptor blockers who were newly prescribed sodium zirconium cyclosilicate or calcium polystyrene sulfonate to treat hyperkalemia at a tertiary referral hospital between August 2020 and April 2022 were enrolled in this single-center, retrospective observational study. The primary outcome measure was angiotensin-converting enzyme inhibitor/angiotensin receptor blocker prescription three months after initiating potassium binders.
Results: In total, 174 patients on angiotensin-converting enzyme inhibitors/angiotensin receptor blockers who were newly administered sodium zirconium cyclosilicate (n = 62) or calcium polystyrene sulfonate (n = 112) were analyzed. The prescription rate of angiotensin-converting enzyme inhibitors /angiotensin receptor blockers at 3 months was significantly higher in the sodium zirconium cyclosilicate group than in the calcium polystyrene sulfonate group (89 vs. 72%). Multivariate logistic regression models showed that sodium zirconium cyclosilicate was independently associated with the primary outcome (odds ratio 2.66, 95% confidence interval 1.05-7.43). The propensity score-matched comparison also showed a significant association between sodium zirconium cyclosilicate and the primary outcome.
Conclusions: Our study suggests that administering sodium zirconium cyclosilicate to patients with hyperkalemia allows for a higher continuation rate of angiotensin-converting enzyme inhibitors/angiotensin receptor blockers than calcium polystyrene sulfonate. These findings suggest that sodium zirconium cyclosilicate has potential benefits for patients with chronic kidney disease receiving renin-angiotensin-aldosterone system inhibitors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s40620-023-01743-4 | DOI Listing |
J Bone Joint Surg Am
January 2025
Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY.
Background: Antiseptic solutions are commonly utilized during total joint arthroplasty (TJA) to prevent and treat periprosthetic joint infection (PJI). The purpose of this study was to investigate which antiseptic solution is most effective against methicillin-sensitive Staphylococcus aureus (MSSA) and Escherichia coli biofilms established in vitro on orthopaedic surfaces commonly utilized in total knee arthroplasty: cobalt-chromium (CC), oxidized zirconium (OxZr), and polymethylmethacrylate (PMMA).
Methods: MSSA and E.
Background: Hyperkalemia, generally defined as serum potassium levels greater than 5.0 mEq/L, poses significant clinical risks, including cardiac toxicity and muscle weakness. Its prevalence and severity increase in patients with chronic kidney disease (CKD), diabetes mellitus, and heart failure (HF), particularly when compounded by medications like Angiotensin converting inhibitors, Angiotensin receptor blockers, and potassium sparing diuretics.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
School of Pharmaceutical Engineering, Shenyang Pharmaceutical University, Benxi, Liaoning Province 117004, PR China. Electronic address:
In this study, the zirconium-based metal organic framework (Zr-MOF) was applied as the adsorbent for phosphorus (P) pollution in water. Then the phosphate-adsorbed metal organic frameworks (MOFs) were used as a recycled raw material and calcined to obtain P-doped MOFs-derived carbon material (ZrP@Zr-BTC). Next, the ZrP@Zr-BTC was used for peroxymonosulfate (PMS) activation for the ceftriaxone sodium degradation.
View Article and Find Full Text PDFEur J Hosp Pharm
December 2024
Department of Pharmacy Practice, Loma Linda University School of Pharmacy, Loma Linda, California, USA
Objective: Sodium polystyrene sulfonate (SPS) and sodium zirconium cyclosilicate (SZC) have been used for treating acute hyperkalaemia. The pharmacodynamic properties of SZC suggest greater theoretical utility in the acute setting than SPS, but there is no clear guidance on an optimal potassium binder. This study evaluated the efficacy of SZC and SPS in the treatment of acute hyperkalaemia.
View Article and Find Full Text PDFJ Card Fail
December 2024
Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan. Electronic address:
Background: To evaluate whether sodium zirconium cyclosilicate (SZC) enables the up-titration of spironolactone without increasing the risk of hyper- and hypokalemia in patients with heart failure with reduced and mildly reduced ejection fraction (HFrEF and HFmrEF) and moderate/severe chronic kidney disease (CKD) who developed hyperkalemia during treatment with suboptimal spironolactone dose.
Methods: The REGISTA-K is a randomized, double-blind, placebo-controlled, multicenter trial that examined the efficacy and safety of SZC in up-titrating spironolactone without the occurrence of hyperkalemia or hypokalemia. A total of 266 patients with HFrEF and HFmrEF and hyperkalemia will be randomized in a 1:1 ratio to receive either SZC or placebo after treating hyperkalemia with SZC at 25 sites in Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!