A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of the Neuroform Atlas stent for wide-necked cerebral aneurysms. | LitMetric

Use of the Neuroform Atlas stent for wide-necked cerebral aneurysms.

Sci Rep

Stroke Center, Henan Provincial People's Hospital, Zhengzhou University, 7 Weiwu Road, Zhengzhou, Henan, China.

Published: August 2023

To investigate the effect and safety of the Neuroform Atlas (NFA) stent in stent-assisted coiling of wide-necked intracranial aneurysms, patients with wide-necked intracranial aneurysms were retrospectively enrolled and treated with the NFA stent-assisted coiling. The modified Rankin scale (mRS) grades and Raymond grades were used to assess the clinical outcomes and aneurysm occlusion degrees, respectively, after embolization and at follow-up. Totally, 122 patients were enrolled with 129 wide-necked aneurysms, and forty-nine (40.2%) patients experienced subarachnoid hemorrhage. A total of 134 NFA stents were deployed in all patients. Immediately after endovascular embolization, the Raymond grade was I in 112 (86.8%), II in 8 (6.2%), and III in 9 (7.0%). Complications occurred in 7 (5.7%) patients, including stent displacement in 2 (1.6%) patients, thrombosis and cerebral infarction in 4 (3.3%), and death in 1 (0.8%). Clinical follow-up was performed in 113 (92.6%) patients 6-30 (mean 21) months after embolization, with the mRS grade 0 in 99 (87.6%) patients, 1 in 7 (6.2%), 2 in 5 (4.4%), and 3 in 2 (1.8%). Good prognosis (mRS ≤ 2) was achieved in 111 (98.2%) patients while poor prognosis (mRS > 2) in two (1.8%). Digital subtraction angiography was conducted in 98 (80.3%) patients with 104 (80.6%) aneurysms 6-30 (mean 21) months after embolization. The Raymond grade was grade I in 94 (90.4%) aneurysms, II in 4 (3.8%), and III in 6 (5.8%). Compared with the Raymond grades immediately after embolization, 93 (89.4%) aneurysms disappeared, 9 (8.7%) remained unchanged in the occlusion status, and 2 (1.9%) were recurrent. In conclusion, the NFA stent may have a high aneurysm occlusion rate and a low complication rate in assisting coiling of wide-necked intracranial aneurysms even though further studies are necessary to prove this.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10444864PMC
http://dx.doi.org/10.1038/s41598-023-40725-1DOI Listing

Publication Analysis

Top Keywords

wide-necked intracranial
12
intracranial aneurysms
12
patients
10
neuroform atlas
8
aneurysms
8
nfa stent
8
stent-assisted coiling
8
coiling wide-necked
8
raymond grades
8
aneurysm occlusion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!