Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The current study goal was to create a precise, sensitive, and validated reverse phase-high performance liquid chromatography (RP-HPLC) method for assessing the direct-acting antiviral daclatasvir (DCV) as well as to evaluate the stability of DCV in both drug and tablet formulations. The current investigation was to display stability indicating methods under different stress conditions, including hydrolysis (acidic, basic, and neutral), oxidation, and photolysis.
Materials And Methods: All experiments were performed on HPLC Agilent 1100 with a stainless steel Hypersil C column having a particle size of 5 μm and a dimension of 4.6 x 250 mm. The mobile phase chosen was acetonitrile: 0.05% o-phosphoric acid (50:50 ) in isocratic mode with 0.7 mL/min flow rate and wavelength 315 nm was selected for detection.
Results: This method was validated for linearity and range, accuracy, precision, limit of detection, limit of quantification, and robustness in accordance with International Council for Harmonisation (ICH) requirements. The results were satisfactory. It was observed that retention time (t) was 3.760 ± 0.01 min. In acidic conditions, DCV degradans show t at 3.863, 4.121, and 4.783 min and tandem mass spectrometry (MS/MS) spectra scans had 339.1, 561.2 fragment ions. In basic condition, DCV degradans show t at 5.188, 5.469 min and MS/MS spectra scans having 294.1, 339.1, 505.2, 527.2 fragment ions. In oxidation conditions, DCV degradans shows t at 4.038 min and MS/MS spectra scans having 301.1 and 339.1 fragment ions were observed.
Conclusion: All the mass fragments exhibited additional degradation observed for different stress conditions. This will help to identify the structure of the degradant and its pathways. No degradation was observed in neutral and photolytic conditions.