A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validated Stability-Indicating RP-HPLC Method for Daclatasvir in Tablets. | LitMetric

Objectives: The current study goal was to create a precise, sensitive, and validated reverse phase-high performance liquid chromatography (RP-HPLC) method for assessing the direct-acting antiviral daclatasvir (DCV) as well as to evaluate the stability of DCV in both drug and tablet formulations. The current investigation was to display stability indicating methods under different stress conditions, including hydrolysis (acidic, basic, and neutral), oxidation, and photolysis.

Materials And Methods: All experiments were performed on HPLC Agilent 1100 with a stainless steel Hypersil C column having a particle size of 5 μm and a dimension of 4.6 x 250 mm. The mobile phase chosen was acetonitrile: 0.05% o-phosphoric acid (50:50 ) in isocratic mode with 0.7 mL/min flow rate and wavelength 315 nm was selected for detection.

Results: This method was validated for linearity and range, accuracy, precision, limit of detection, limit of quantification, and robustness in accordance with International Council for Harmonisation (ICH) requirements. The results were satisfactory. It was observed that retention time (t) was 3.760 ± 0.01 min. In acidic conditions, DCV degradans show t at 3.863, 4.121, and 4.783 min and tandem mass spectrometry (MS/MS) spectra scans had 339.1, 561.2 fragment ions. In basic condition, DCV degradans show t at 5.188, 5.469 min and MS/MS spectra scans having 294.1, 339.1, 505.2, 527.2 fragment ions. In oxidation conditions, DCV degradans shows t at 4.038 min and MS/MS spectra scans having 301.1 and 339.1 fragment ions were observed.

Conclusion: All the mass fragments exhibited additional degradation observed for different stress conditions. This will help to identify the structure of the degradant and its pathways. No degradation was observed in neutral and photolytic conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10445227PMC
http://dx.doi.org/10.4274/tjps.galenos.2022.87393DOI Listing

Publication Analysis

Top Keywords

dcv degradans
12
ms/ms spectra
12
spectra scans
12
fragment ions
12
rp-hplc method
8
stress conditions
8
conditions dcv
8
min ms/ms
8
degradation observed
8
dcv
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!