The development of microfluidic systems for biological assays presents challenges, particularly in adapting traditional optical absorbance assays to smaller volumes or to microfluidic formats. This often requires assay modification or translation to a fluorescence version, which can be impractical. To address this issue, our group has developed the μChopper device, which uses microfluidic droplet formation as a surrogate for an optical beam chopper, allowing for lock-in analysis and improved limits of detection with both absorbance and fluorescence optics without modifying the optical path length. Here, we have adapted the μChopper to low-cost optics using a light-emitting diode (LED) source and photodiode detector, and we have fabricated the pnuematically valved devices entirely by 3D printing instead of traditional photolithography. Using a hybrid device structure, fluidic channels were made in polydimethylsiloxane (PDMS) by moulding onto a 3D-printed master then bonding to a prefabricated thin layer, and the pneumatic layer was directly made of 3D-printed resin. This hybrid structure allowed an optical slit to be fabricated directly under fluidic channels, with the LED interfaced closely above the channel. Vacuum-operated, normally closed valves provided precise temporal control of droplet formation from 0.6 to 2.0 Hz. The system was validated against the standard plate reader format using a colorimetric fructosamine assay and by quantifying fructosamine in human serum from normal and diabetic patients, where strong correlation was shown. Showing a standard benefit of microfluidics in analysis, the device required 6.4-fold less serum volume for each assay. This μChopper device and lower cost optical system should be applicable to various absorbance based assays in low volumes, and the reliance on inexpensive 3D printers makes it more accessible to users without cleanroom facilities.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10530610 | PMC |
http://dx.doi.org/10.1039/d3an01149f | DOI Listing |
Best Pract Res Clin Anaesthesiol
March 2024
Cardiothoracic Anesthesia, Anesthesiology Department, College of Medicine, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia; Cardiothoracic Anaesthesia Unit, Department of Anaesthesia, Surgical Intensive Care and Pain Medicine, College of Medicine, Mansoura University, Mansour, Egypt. Electronic address:
Innovations and challenges for lung separation or isolation have evolved during the last few years. In this chapter, we present the up-to-date, robust evidence available during the previous five years supporting the positions of the different devices, techniques, and tricks for their use in adult and pediatric patients undergoing various thoracic surgical interventions. Additionally, we presented an update on lung isolation in patients with airway difficulty and the suggested training level to master these techniques.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Research Institute for Intelligent Wearable Systems, School of Fashion and Textiles, The Hong Kong Polytechnic University, Kowloon, 999077, China.
Rapid temperature contrast hydrotherapy by water immersion has been utilized by athletes for effective sports recovery. However, its application at some training or competition venues is limited by high water consumption, bucky size, personal hygiene, and inconvenience. Here, a novel portable system equipped with highly effective, lightweight, and hygienic wearable fluidic fabric device is reported, that replaces direct water immersion.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen, 518172, P. R. China.
Soft capacitive sensors are widely utilized in wearable devices, flexible electronics, and soft robotics due to their high sensitivity. However, they may suffer delamination and/or debonding due to their low interfacial toughness. In addition, they usually exhibit a small measurement range resulting from their limited stiffness variation range.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
School of Medicine, Huanghe Science and Technology University, Zhengzhou 450061, P. R. China.
Silver nanowire (Ag NW)-based elastic conductors have been considered a promising candidate for key stretchable electrodes in wearable devices. However, the weak interface interaction of Ag NWs and elastic substrates leads to poor durability of electronic devices. For everyday usage, an additional self-healing ability is required to resist scratching and damage.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!