Predicting successful ultrasound-guided biopsy of liver lesions.

Abdom Radiol (NY)

Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA, 02215, USA.

Published: November 2023

AI Article Synopsis

  • This study looked at how to make liver biopsies using ultrasound better and easier.
  • They checked data from 501 patients and found that 86% of the biopsies were successful.
  • Smaller, deeper liver lesions and certain locations made it harder to perform the biopsy, especially when there were fewer lesions to target.

Article Abstract

Objectives: To determine the factors that affect successful ultrasound-guided biopsy of liver lesions and build a model predicting feasibility of US-guided liver biopsy.

Methods: This is IRB-approved HIPAA-compliant retrospective review of consecutive ultrasound-guided targeted liver biopsies performed or attempted between 1/2018 and 9/2020 at a single tertiary academic institution with a total of 501 patients included. Mann-Whitney and chi-square tests were used to compare continuous and categorical variables, respectively. Logistic regression model was built to predict feasibility of successful ultrasound-guided biopsy.

Results: Liver lesion biopsy was successfully performed with US guidance in 429/501 (86%) patients. Lesions not amenable for US biopsy were smaller (median size 1.6 cm vs 3.3 cm, p < 0.0001) and deeper within the liver (median depth 9.0 cm vs 5.8 cm, p < 0.0001). The technical success rate was lowest for lesions in segment II (40/53, 75%), while lesions in segment IVb (87/91, 96%) had highest success rate (p < 0.003). US targeting in patients with 1 or 2 lesions was less feasible than in patients with 3 or more lesions, 126/180 (70%) vs. 303/321 (94%), (p < 0.0001). Model including lesion size, depth, location, and number of lesions predicts feasibility of US-guided biopsy with Area under the ROC curve (AUC) = 0.92.

Conclusions: Linear logistic regression model that includes lesion size, depth and location, and number of lesions is highly successful in predicting feasibility of ultrasound-guided biopsy for liver lesions. Smaller lesions, deeper lesions, and lesions in segment II and VIII in patients with less than 3 lesions were less feasible for ultrasound-guided biopsy of liver lesions.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00261-023-04017-6DOI Listing

Publication Analysis

Top Keywords

ultrasound-guided biopsy
16
biopsy liver
16
liver lesions
16
patients lesions
16
lesions
15
successful ultrasound-guided
12
lesions segment
12
liver
8
predicting feasibility
8
feasibility us-guided
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!