Arteriosclerosis, which appears as a hardened and narrowed artery with plaque buildup, is the primary cause of various cardiovascular diseases such as stroke. Arteriosclerosis is often evaluated by clinically measuring the pulse wave velocity (PWV) using a two-point approach that requires bulky medical equipment and a skilled operator. Although wearable photoplethysmographic sensors for PWV monitoring are developed in recent years, likewise, this technique is often based on two-point measurement, and the signal can easily be interfered with by natural light. Herein, a single-point strategy is reported based on stable fingertip pulse monitoring using a flexible iontronic pressure sensor for heart-fingertip PWV (hfPWV) measurement. The iontronic sensor exhibits a high pressure-resolution on the order of 0.1 Pa over a wide linearity range, allowing the capture of characteristic peaks of fingertip pulse waves. The forward and reflected waves of the pulse are extracted and the time difference between the two waves is computed for hfPWV measurement using Hiroshi's method. Furthermore, a hfPWV-based model is established for arteriosclerosis evaluation with an accuracy comparable to that of existing clinical criteria, and the validity of the model is verified clinically. The work provides a reliable technique that can be used in wearable arteriosclerosis assessment systems.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adhm.202301838DOI Listing

Publication Analysis

Top Keywords

fingertip pulse
12
arteriosclerosis assessment
8
pulse monitoring
8
iontronic sensor
8
hfpwv measurement
8
arteriosclerosis
5
pulse
5
assessment based
4
based single-point
4
single-point fingertip
4

Similar Publications

The physiological sequelae of pre-term birth might influence the responses of this population to hypoxia. Moreover, identifying variables associated with development of acute mountain sickness (AMS) remains a key practically significant area of altitude research. We investigated the effects of pre-term birth on nocturnal oxygen saturation ( ) dynamics and assessed the predictive potential of nocturnal -related metrics for morning AMS in 12 healthy adults with gestational age < 32 weeks (pre-term) and 12 term-born control participants.

View Article and Find Full Text PDF

Accuracy of Rhythm Diagnostic Systems' MultiSense in Detection of Arterial Oxygen Saturation and Respiratory Rate During Hypoxia in Humans: Effects of Skin Color and Device Localization.

Sensors (Basel)

December 2024

Biomedicine Research Center of Strasbourg (CRBS), UR 3072, "Mitochondria, Oxidative Stress and Muscle Plasticity", Faculty of Medicine, University of Strasbourg, 67000 Strasbourg, France.

The continuous monitoring of oxygen saturation (SpO) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations.

View Article and Find Full Text PDF

Comparative Effects of Different Exercise Types on Cardiovascular Health and Executive Function in Sedentary Young Individuals.

Med Sci Sports Exerc

January 2025

Guangdong Provincial Key Laboratory of Physical Activity and Health Promotion, Guangzhou Sport University, Guangzhou, Guangdong, CHINA.

Purpose: The present study aimed to compare the impacts of different exercise types on cardiovascular health and executive function in sedentary young individuals, and to determine the associations between cardiovascular function and executive function (EF) after exercise.

Methods: Sixty-three sedentary participants were randomly divided into high-intensity interval training (HIIT), moderate-intensity continuous training (MICT), resistance exercise (RE), and control groups. Macro- and microvascular endothelial function were assessed using brachial artery flow-mediated dilation and fingertip reactive hyperemia index, respectively.

View Article and Find Full Text PDF

In the early stages of atrial fibrillation (AF), most cases are paroxysmal (pAF), making identification only possible with continuous and prolonged monitoring. With the advent of wearables, smartwatches equipped with photoplethysmographic (PPG) sensors are an ideal approach for continuous monitoring of pAF. There have been numerous studies demonstrating successful capture of pAF events, especially using deep learning.

View Article and Find Full Text PDF

Objective: We study the changes in morphology of the photoplethysmography (PPG) signals-acquired from a select group of South Asian origin-through a low-cost PPG sensor, and correlate it with healthy aging which allows us to reliably estimate the vascular age and chronological age of a healthy person as well as the age group he/she belongs to.

Methods: Raw infrared PPG data is collected from the finger-tip of 173 appar- ently healthy subjects, aged 3-61 years, via a non-invasive low- cost MAX30102 PPG sensor. In addition, the following metadata is recorded for each subject: age, gender, height, weight, family history of cardiac disease, smoking history, vitals (heart rate and SpO2).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!