A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

How Does Pupil Size Affect Lens and Corneal Densitometry Measured by Scheimpflug Tomography? | LitMetric

Objectives: To investigate the effects of pupil diameter on the evaluation of lens and corneal densitometry measured by Scheimpflug tomography.

Materials And Methods: This cross-sectional and comparative study used the right eyes of 32 participants. Corneal and lenticular optical densitometries, corneal volume, anterior segment volume, and anterior chamber depth measurements were taken with the Scheimpflug imaging system when the pupils were mid-dilated and fully dilated. The results were statistically compared.

Results: The mean lens density was 19.20±3.05 when the pupils were mid-dilated (mean pupil diameter 2.98±0.89 mm) and 23.25±3.88 at full dilation (mean pupil diameter 5.01±0.92 mm) (p<0.001). The mean corneal density was 16.15±0.99 with mid-dilated pupils and 16.38±0.95 with fully dilated pupils (p=0.065). Anterior chamber depth and anterior segment volume measurements increased with larger pupil diameter (p<0.05).

Conclusion: The lens densitometry values increased with an increase in pupil diameter. The corneal density measurements increased minimally but the differences were not statistically significant. This study revealed that lens densitometry was significantly affected by pupil diameter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10442744PMC
http://dx.doi.org/10.4274/tjo.galenos.2022.42724DOI Listing

Publication Analysis

Top Keywords

pupil diameter
12
lens corneal
8
corneal densitometry
8
densitometry measured
8
measured scheimpflug
8
volume anterior
8
pupils mid-dilated
8
pupil
4
pupil size
4
size affect
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!