Objective: To present a systematic review of randomized controlled trials which summarizes the effects of community-based resistance, balance, and multi-component exercise interventions on the parameters of functional ability (e.g., lower extremities muscle strength, balance performance and mobility).
Methods: This PROSPERO-registered systematic review (registration no. CRD42023434808) followed the PRISMA guidelines. Literature search was conducted in Cochrane, Embase, Ovid Medline, PEDro, Pubmed, Science Direct, Scopus and Web of Science. We included RCTs that investigated the following interventions: lower extremity strengthening, balance and multi-component exercise interventions on ambulatory community-dwelling adults aged ≥65 years.
Results: Lower extremity strengthening exercises revealed significant effects on the strength of lower extremity, balance outcomes and mobility. Balance exercises reduce the rate of injurious falls, improve static, dynamic and reactive balance, lower extremity strength as well as mobility. Multi-component exercise training reduces medically-attended injurious falls and fallers, incidence of falls, fall-related emergency department visits as well as improves mobility, balance, and lower extremity strength.
Conclusion: Physical exercises are effective in improving the components of balance, lower extremity strength, mobility, and reducing falls and fall-related injuries. Further research on fall prevention in low-income countries as well as for older adults in vulnerable context is needed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10435089 | PMC |
http://dx.doi.org/10.3389/fpubh.2023.1209319 | DOI Listing |
Sensors (Basel)
December 2024
Faculty of Medicine, Department of Kinesiology, Université Laval, Quebec City, QC G1V OA6, Canada.
Foot strike patterns influence vertical loading rates during running. Running retraining interventions often include switching to a new foot strike pattern. Sudden changes in the foot strike pattern may be uncomfortable and may lead to higher step-to-step variability.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki 889-2192, Japan.
Active ankle orthoses which have been designed over the past few years by diverse sources were critically reviewed in this paper. It begins by providing an overview of the anatomy of the ankle joint complex, establishing a basis for understanding the subsequent discussion on the research challenges and design difficulties associated with developing active ankle orthosis devices. The review systematically examined the mechanisms, actuation methods, and control strategies utilized in these orthosis devices.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
Advancements in science and technology have driven the growing use of robots in daily life, with Portable-Powered Lower Limb Exoskeletons (PPLLEs) emerging as a key innovation. The selection of mechanisms, control strategies, and sensors directly influences the overall performance of the exoskeletons, making it a crucial consideration for research and development. This review examines the current state of PPLLE research, focusing on the aspects of mechanisms, control strategies, and sensors.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Institute for Health and Sport, Victoria University, Melbourne, VIC 3000, Australia.
The continuous, automated monitoring of sensor-based data for walking capacity and mobility has expanded gait analysis applications beyond controlled laboratory settings to real-world, everyday environments facilitated by the development of portable, cost-efficient wearable sensors. In particular, the integration of Inertial Measurement Units (IMUs) into smart shoes has proven effective for capturing detailed foot movements and spatiotemporal gait characteristics. While IMUs enable accurate foot trajectory estimation through the double integration of acceleration data, challenges such as drift errors necessitate robust correction techniques to ensure reliable performance.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, 20133 Milano, Italy.
Vertical jump height from a countermovement jump is a widespread metric to assess the lower limb functionality. Motion capture systems and force platforms are considered gold standards to estimate vertical jump height; however, their use in ecological settings is limited. This study aimed to evaluate the feasibility of low-sampling-rate inertial measurement units as an alternative to the gold standard systems.