A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrochemical Detection of Cortisol by Silver Nanoparticle-Modified Molecularly Imprinted Polymer-Coated Pencil Graphite Electrodes. | LitMetric

The sensitive cortisol detection by an electrochemical sensor based on silver nanoparticle-doped molecularly imprinted polymer was successfully improved. This study describes the method development for cortisol detection in both aqueous solution and biological samples using molecularly imprinted poly(hydroxyethyl methacrylate--methacryloyl-(l)-histidine methyl ester)-coated pencil graphite electrodes modified with silver nanoparticles (AgNPs) by differential pulse voltammetry (DPV). The cortisol-imprinted pencil graphite electrode (PGE) has a large surface area because of doped AgNPs with enhanced electroactivity. The prepared molecularly imprinted polymer was characterized by scanning electron microscopy. The DPV response of the synthesized electrode with outstanding electrical conductivity was clarified. Cortisol-imprinted polymer-coated PGEs (MIP), cortisol-imprinted polymer-coated PGEs with AgNPs (MIP@AgNPs), and nonimprinted polymer-coated PGEs with AgNPs (NIP@AgNPs) were evaluated for sensitive and selective detection of cortisol in aqueous solution. Five different cortisol concentrations (0.395, 0.791, 1.32, 2.64, and 3.96 nM) were applied to the MIP@AgNPs, and signal responses were detected by the DPV with a regression coefficient () value of 0.9951. The modified electrode showed good electrocatalytic activity toward cortisol for the linear concentration range from 0.395 to 3.96 nM, and a low limit of detection was recorded as 0.214 nM. The results indicate that the MIP@AgNPs sensor has great potential for sensitive and selective cortisol determination in biological samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10433476PMC
http://dx.doi.org/10.1021/acsomega.3c02472DOI Listing

Publication Analysis

Top Keywords

molecularly imprinted
16
pencil graphite
12
polymer-coated pges
12
detection cortisol
8
graphite electrodes
8
cortisol detection
8
imprinted polymer
8
aqueous solution
8
biological samples
8
cortisol-imprinted polymer-coated
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!