In this study, we explored the potential of hydrodynamic cavitation (HC) for use in dissolution of liquid and powder detergents. For this, microfluidic and polyether ether ketone (PEEK) tube HC reactors with different configurations were employed, and the results from the reactors were compared with a magnetic stirrer, as well as a tergotometer. According to our results PEEK tube HC reactors present the best performance for dissolution of liquid and powder detergents. In the case of liquid detergent, for the same level of initial concentration and comparable final dissolution, the PEEK tube consumed 16.7 and 70% of the energy and time of a tergotometer and 16.7 and 14.8% of that of a magnetic stirrer, respectively. In the case of powder detergent, the PEEK tube used 12% less power than a tergotometer and 81.2% less power than a magnetic stirrer. Additionally, the time required to dissolve the detergent was reduced significantly from 1200 s in the tergotometer and 1800 s in the magnetic stirrer to just 50 s in the PEEK tube. These results suggest that HC could significantly improve the dissolution rate of liquid and powder detergents and energy consumption in washing machines.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10433497 | PMC |
http://dx.doi.org/10.1021/acsomega.3c03517 | DOI Listing |
J Chromatogr A
May 2024
Departamento de Química da Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto (DQ-FFCLRP), Universidade de São Paulo, Ribeirão Preto, São Paulo, Brazil.
Mass spectrometry is characterized by its high sensitivity, ability to measure very low analyte concentrations, specificity to distinguish between closely related compounds, availability to generate high-throughput methods for screening, and high multiplexing capacity. This technique has been used as a platform to analyze fluid biomarkers for Alzheimer's disease. However, more effective sample preparation procedures, preferably antibody-independent, and more automated mass spectrometry platforms with improved sensitivity, chromatographic separation, and high throughput are needed for this purpose.
View Article and Find Full Text PDFAnal Chem
November 2023
NMR/X-Ray Platform for Convergence Research (NMRCoRe), KU Leuven, Leuven 3001, Belgium.
High-pressure nuclear magnetic resonance (NMR) spectroscopy finds remarkable applications in catalysis, protein biochemistry and biophysics, analytical chemistry, material science, energy, and environmental control but requires expensive probe heads and/or sample cells. This contribution describes the design, construction, and testing of a low-cost 5 mm NMR tube suitable for high-pressure NMR measurements of up to 30 MPa. The sample cell comprises a standard, 5 mm single-crystal sapphire tube that has been fitted to a section of a relatively inexpensive polyether ether ketone (PEEK) HPLC column.
View Article and Find Full Text PDFMikrochim Acta
September 2023
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
In order to improve the extraction ability of carbon fibers (CFs) for microextraction of polycyclic aromatic hydrocarbons (PAHs), biochar nanospheres derived from glucose were in-situ grown onto the surface of CFs via hydrothermal synthesis. The surface morphology and elemental composition of biochar nanospheres-CFs were investigated by scanning electron microscopy and X-ray photoelectron spectroscopy. Thereafter, the biochar nanosphere-CFs were pulled into the polyetheretherketone tube for solid-phase microextraction, and the tube was combined with high-performance liquid chromatography-diode array detector to online detect PAHs.
View Article and Find Full Text PDFACS Omega
August 2023
Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
In this study, we explored the potential of hydrodynamic cavitation (HC) for use in dissolution of liquid and powder detergents. For this, microfluidic and polyether ether ketone (PEEK) tube HC reactors with different configurations were employed, and the results from the reactors were compared with a magnetic stirrer, as well as a tergotometer. According to our results PEEK tube HC reactors present the best performance for dissolution of liquid and powder detergents.
View Article and Find Full Text PDFTalanta
March 2023
Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, University of Sao Paulo, Ribeirao Preto, SP, Brazil. Electronic address:
Current research efforts at neurological diseases have focused on identifying novel biomarkers to aid in diagnosis, to provide accurate prognostic information, and to monitor disease progression. This study presents the direct coupling of fiber-in-tube solid-phase microextraction to tandem mass spectrometry as a reliable method to determine amyloid beta peptides (Aβ38, Aβ40, and Aβ42) as biomarkers for Alzheimer's disease in cerebrospinal fluid (CSF) samples. To obtain the biocompatible fiber-in-tube SPME capillary, a PEEK tube segment was longitudinally packed with fine fibers [nitinol wires coated with a zwitterionic polymeric ionic liquid], to act as selective extraction medium.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!