A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

B-mode transorbital ultrasonography for the diagnosis of idiopathic intracranial hypertension: an updated systematic review and meta-analysis. | LitMetric

Objectives: This systematic review and meta-analysis aimed to evaluate the role of B-mode transorbital ultrasonography (TOS) for the diagnosis of idiopathic intracranial hypertension (IIH) in adults.

Methods: MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials (CENTRAL) (1966-May 2022) were searched to identify studies reporting ultrasonographic data about the optic nerve sheath diameter (ONSD) and optic disc elevation (ODE) in adults with IIH compared to subjects without IIH. The quality of the included studies was evaluated by the Newcastle-Ottawa Quality.

Results: Fifteen studies were included (total of 439 patients). The values of ODE ranged from 0.6 to 1.3 mm in patients with IIH. The values of ONSD ranged from 4.7 to 6.8 mm in IIH patients and from 3.9 to 5.7 mm in controls. In IIH patients, the ONSD was significantly higher compared to controls (standardized mean difference: 2.5 mm, 95% confidence interval (CI): 1.6-3.4 mm). Nine studies provided data about the presence of papilledema and the pooled prevalence was 95% (95% CI, 92-97%).

Conclusions: In adults, the thickness of ONSD and the entity of ODE were significantly associated with IIH. B-mode TOS enables to noninvasively detect increased ICP and should be performed, potentially routinely, in any patient with suspected IIH.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10072-023-07016-zDOI Listing

Publication Analysis

Top Keywords

b-mode transorbital
8
transorbital ultrasonography
8
diagnosis idiopathic
8
idiopathic intracranial
8
intracranial hypertension
8
systematic review
8
review meta-analysis
8
iih
8
iih patients
8
ultrasonography diagnosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!