Pitch is a perceptual rather than physical phenomenon, important for spoken language use, musical communication, and other aspects of everyday life. Auditory stimuli can be designed to probe the relationship between perception and physiological responses to pitch-evoking stimuli. One technique for measuring physiological responses to pitch-evoking stimuli is the frequency following response (FFR). The FFR is an electroencephalographic (EEG) response to periodic auditory stimuli. The FFR contains nonlinearities not present in the stimuli, including correlates of the amplitude envelope of the stimulus; however, these nonlinearities remain undercharacterized. The FFR is a composite response reflecting multiple neural and peripheral generators, and their contributions to the scalp-recorded FFR vary in ill-understood ways depending on the electrode montage, stimulus, and imaging technique. The FFR is typically assumed to be generated in the auditory brainstem; there is also evidence both for and against a cortical contribution to the FFR. Here a methodology is used to examine the FFR correlates of pitch and the generators of the FFR to stimuli with different pitches. Stimuli were designed to tease apart biological correlates of pitch and amplitude envelope. FFRs were recorded with 256-electrode EEG nets, in contrast to a typical FFR setup which only contains a single active electrode. Structural MRI scans were obtained for each participant to co-register with the electrode locations and constrain a source localization algorithm. The results of this localization shed light on the generating mechanisms of the FFR, including providing evidence for both cortical and subcortical auditory sources.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.neuroimage.2023.120330 | DOI Listing |
Pharmaceutics
January 2025
Dipartimento di Scienze e Tecnologie Biologiche Chimiche e Farmaceutiche (STEBICEF), University of Palermo, Via Archirafi 32, 90123 Palermo, Italy.
: Following tooth extraction, resveratrol (RSV) can support healing by reducing inflammation and microbial risks, though its poor solubility limits its effectiveness. This study aims to develop a solid nanocomposite by embedding RSV in lipid nanoparticles (mLNP) within a hydrophilic matrix, to the scope of improving local delivery and enhancing healing. Hydroxyapatite (HXA), often used as a bone substitute, was added to prevent post-extraction alveolus volume reduction.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Department of Cardiology, School of Medicine, Kastamonu University, Kastamonu 37150, Turkey.
: Fractional Flow Reserve (FFR) is a method that enables the hemodynamic assessment of coronary artery stenosis. The Systemic Inflammatory Response Index (SIRI) is a new marker calculated by multiplying the neutrophil-to-lymphocyte ratio (NLR) with the monocyte count. It is indicative of the presence and severity of coronary artery disease.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
January 2025
Department of Cardiology, Lausanne University Hospital and University of Lausanne, 1011 Lausanne, Switzerland.
Cardiac computed tomography (CT) has become an essential tool in the pre-procedural planning and optimization of coronary interventions. Its non-invasive nature allows for the detailed visualization of coronary anatomy, including plaque burden, vessel morphology, and the presence of stenosis, aiding in precise decision making for revascularization strategies. Clinicians can assess not only the extent of coronary artery disease but also the functional significance of lesions using techniques like fractional flow reserve (FFR-CT).
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
January 2025
Department of Cardiovascular Surgery, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake, Toyoake 470-1192, Aichi, Japan.
Fractional flow reserve (FFR) has been well validated as a modality for evaluating myocardial ischemia, demonstrating the superiority of FFR-guided percutaneous coronary intervention (PCI) over conventional angiography-guided PCI. As a result, the strategy for coronary artery bypass grafting (CABG) is shifting toward FFR guidance. However, the advantage of FFR-guided CABG over angiography-guided CABG remains unclear.
View Article and Find Full Text PDFSci Rep
January 2025
Thermal and Energetic Systems Studies Laboratory (LESTE), LR99ES31, College of Engineering, University of Monastir, 5000, Monastir, Tunisia.
Using the RANS approach with the standard k-ω turbulence model, this study offers a novel investigation into the dynamic and thermal properties of turbulent impinging jet arrays. Our study examines the combined effect of the number of jets (N) and the jet-jet spacing (S) on flow mechanisms and heat transfer performance, which is unique compared to previous research that frequently focuses on the individual effects of parameters. Through the investigation of the turbulent kinetic energy, friction coefficient, velocity contours, streamlines, pressure contours, and local and mean Nusselt numbers, we provide important information about how these parameters impact flow dynamics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!