Conduction system pacing in difficult cardiac anatomies: Systematic approach with the 3D electroanatomic mapping guide.

Indian Pacing Electrophysiol J

Arrhythmia and Electrophysiological Unit, Department of Cardiology, Santa Maria della Misericordia Hospital, Rovigo, Italy. Electronic address:

Published: August 2023

Introduction: Restoring physiological cardiac electrical activity in patients with conduction disease can be crucial for the survival and quality of life. Conduction system pacing (CSP) is a valuable option, although it is limited by technical challenges in difficult anatomies. 3D electroanatomical mapping (3D-EAM) can support CSP ensuring high electro-anatomical precision and low fluoroscopy.

Objectives: We evaluated the feasibility and effectiveness of a systematic 3D-EAM use to guide CSP in difficult anatomical scenarios (highly dilated atria, congenital cardiomyopathies, failed biventricular implants (BiV) and pacing-induced cardiomyopathy (PICM)).

Methods: Forty-three consecutive patients (27 males, 75 ± 10 years old) with standard pacing indications and difficult anatomical scenarios were included. The right atrium, His cloud, and atrio-ventricular septum were reconstructed by 3D-EAM. The His bundle (HB) was the initial target, while left bundle branch area pacing (LBBAP) was aimed at in case of unsatisfactory parameters, sub-optimally paced QRS, or impossibility of reaching the HB.

Results: CSP was successful in 37 (86%) patients (15 HBP; 22 LBBAP). Mean mapping, fluoroscopy, and procedural times were 18 ± 7 min, 7 ± 5 min, 98 ± 47 min, respectively. The mean pacing threshold, R wave sensing, and pacing impedance of CSP lead were 1.2 ± 0.5V@0.5ms, 11.4 ± 6.2 mV, 736 ± 306 Ω, respectively. Baseline and paced QRS were 139 ± 38 ms and 114 ± 23 ms, respectively. No procedural complications were observed.

Conclusions: 3D-EAM allowed the accurate definition of the His cloud and high ventricular septum and effectively guided CSP. It facilitated CSP in complex anatomies, with a procedural success rate of 86%. The results were satisfactory and reproducible, with acceptable fluoroscopy and procedural times.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10685099PMC
http://dx.doi.org/10.1016/j.ipej.2023.08.006DOI Listing

Publication Analysis

Top Keywords

conduction system
8
system pacing
8
difficult anatomical
8
anatomical scenarios
8
paced qrs
8
fluoroscopy procedural
8
procedural times
8
csp
7
pacing
6
difficult
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!