A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analytical method development supported by DoE-DS approach for enantioseparation of (S,S)- and (R,R)-moxifloxacin. | LitMetric

Analytical method development supported by DoE-DS approach for enantioseparation of (S,S)- and (R,R)-moxifloxacin.

J Pharm Biomed Anal

University of Belgrade, Faculty of Pharmacy, Department of Drug Analysis, Vojvode Stepe 450, Belgrade, Serbia.

Published: October 2023

In this paper, method for enantiomeric purity testing of fourth-generation fluoroquinolone, moxifloxacin hydrochloride, was developed and validated. Exceptional enantioselectivity for this assay was achieved using cyclodextrin type Chiral Stationary Phase (CSP), phenylcarbamate-β-cyclodextrin CSP, and mobile phase consisted of acetonitrile and triethylammonium acetate (TEAA) buffer. Analytical Quality by Design (AQbD) methodology, comprising Design of Experiments (DoE) - Design Space (DS) approach, was used for method development. In order to select appropriate Critical Method Parameters (CMPs), risk assessment was done using combined three step strategy that involved Ishikawa diagram - CNX (Control, Noise and eXperimental) - FMEA (Failure Mode and Effect Analysis). Three CMPs were further selected and investigated in this study: acetonitrile content in the mobile phase (30-50%, v/v), triethylamine content in the TEAA buffer (0.1-1.5%, v/v) and aqueous phase pH (3.5-4.5). Monte Carlo simulations were performed and 3D-DS was computed. One point situated in the center of 3D-DS was selected as working point for method validation, with the following values of CMPs: acetonitrile content in the mobile phase set to 37% (v/v), triethylamine content in TEAA 0.8% and pH value of the aqueous phase set at 4.0. Also, 2D-DS was created (with fixed one factor - pH value of aqueous phase at 4.0) which also gave us confirmation that the selection of working conditions was suitable. The proposed enantioselective method was further on tested for its quantitative robustness, as well as for its suitability for the intended purpose through validation studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2023.115645DOI Listing

Publication Analysis

Top Keywords

mobile phase
12
aqueous phase
12
method development
8
teaa buffer
8
acetonitrile content
8
content mobile
8
v/v triethylamine
8
triethylamine content
8
content teaa
8
phase set
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!