Objectives: To evaluate the influence of the dental arch and cutting-off and rescanning procedures on the accuracy of complete-arch implant scans in partially edentulous arches.
Material And Methods: A maxillary and a mandibular partially edentulous typodont with implant abutment analogs placed in the right and left first molar and right central incisor sites were digitized to create reference models by using an industrial optical scanner (7 Series Desktop Scanner; Dentalwings). Two experimental groups were scanned using an intraoral scanner (IOS) (TRIOS 4; 3Shape A/S): the Maxillary group (Mx) and the Mandibular group (Mb). Four subgroups were generated depending on the number of rescanned mesh holes: No holes (Mx-G0, Mb-G0), 1 hole (Mx-G1, Mb-G1), 2 holes (Mx-G2, Mb-G2) and 3 holes (Mx-G3, Mb-G3). A 3-dimensional metrology software (Geomagic Control X; 3D Systems) was used to measure the difference between the reference and the experimental scans computing the root mean square (RMS) error calculation. Two-way ANOVA and a post-hoc Tukey test were used to analyze the trueness data (α=0.05). Levene test was used to evaluate the prevision (α=0.05).
Results: The Mx group obtained a trueness mean value of 54 ± 17 µm and a mean precision value of 54 ± 17 µm, while the Mb group presented a trueness mean value of 67 ± 23 µm and a mean precision value of 66 ± 22 µm. The Mx group demonstrated significantly better trueness than the Mb group (P<.001). The G0 and G1 subgroups had the highest trueness values among the subgroups tested. No significant difference was observed between G0 and G1, G1 and G2, and G2 and G3 subgroups in trueness and precision. However, the G0 had significantly better trueness and precision values compared to G2 and G3 subgroups. In addition, the G1 had significantly better trueness values than the G3 subgroup. However, the Levene test revealed no difference in the precision mean values among the subgroups tested.
Conclusions: Implant scanning trueness was affected by the dental arch and the number of rescanned mesh holes using the IOS tested. A higher number of rescanned mesh holes decreased the scanning trueness. The stitching algorithm of the IOS software tested after the mesh hole scan demonstrated a significant error, especially when multiples mesh holes are involved in the same arch.
Clinical Significance: Given that cutting-off and rescanning techniques can reduce trueness, clinicians should consider whether these techniques are necessary in complete digital workflows. This is particularly important when fabricating multiple single implant-supported restorations in the same arch.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jdent.2023.104667 | DOI Listing |
BMC Oral Health
January 2025
Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, Graz, 8010, Austria.
Aims: Bone preservation is a requirement for long-term stability of dental prostheses, which is all the more important in the posterior mandible, given the particular challenges these areas pose to prosthetic treatment. The objective was to investigate the implications of different prostheses on the atrophy of posterior alveolar bone after tooth loss.
Materials And Methods: A total of 457 treatment cases were retrieved from the medical documentation and information network.
J Prosthet Dent
January 2025
Full Professor, Department of Restorative Dentistry, University of Washington, Seattle, Wash.
Statement Of Problem: The impact of free gingival graft (FGG) dimensions on the postsurgical shrinkage of keratinized tissue width (KTW) and surface area in posterior implant sites is unclear. Standardized assessments of how graft dimensions influence KTW and surface area shrinkage rates over a 6-month period after FGG are lacking.
Purpose: The purpose of this prospective parallel cohort study was to examine the impact of the graft dimensions on the postsurgical shrinkage of KTW and surface area over a 6-month follow-up period after FGG in the posterior regions.
J Dent Sci
December 2024
School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Background/purpose: The accuracy of intraoral scanners (IOSs) plays a crucial role in the success of final restorations in digital workflows. Previous studies have shown that numerous factors affect the accuracy of IOSs. Most studies have evaluated the accuracy of IOS under one restoration condition.
View Article and Find Full Text PDFJ Adv Prosthodont
December 2024
[This corrects the article on p. 302 in vol. 16, PMID: 39512875.
View Article and Find Full Text PDFCureus
December 2024
Prosthodontics, SRM Kattankulathur Dental College and Hospital, SRM Institute of Science and Technology, Chengalpattu, IND.
Background and objective Alveolar ridge defects in partially edentulous patients present significant challenges in prosthodontic treatment planning. Seibert's classification system provides a structured approach to categorizing these defects based on the buccolingual and apico-coronal dimensions of the ridge. Accurate classification is crucial for determining appropriate treatment strategies for implant placement, fixed prosthesis, or tissue augmentation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!