Though the traditional fault diagnosis method of T-connected transmission lines can identify the faults inside and outside the area, it can not identify the specific branches. To improve the accuracy and reliability of fault diagnosis of T-connection transmission lines, a new method is proposed to identify specific faulty branches of T-connection transmission lines based on multi-scale traveling wave reactive power and random forest. Based on the S-transform, the mean and sum ratios of the corresponding short-time series traveling wave reactive powers of each two traveling wave protection units at multiple frequencies are calculated respectively to form the fault feature vector sample set of the T-connection transmission line. A random forest fault branch identification model is established, and it is trained and tested by the fault feature sample set of T-connection transmission line to identify the fault branch. The simulation results show that the proposed algorithm can identify the branch where the fault is located inside and outside the protection zone of T-connection transmission line quickly and accurately under various working conditions. This method also shows good performance to identify faults even under the situation of CT saturation, noise influence and data loss.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10437885 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0284937 | PLOS |
PLoS One
August 2023
State Grid YiliYihe Electric Power Supply Company, Yining, Xinjiang, China.
Though the traditional fault diagnosis method of T-connected transmission lines can identify the faults inside and outside the area, it can not identify the specific branches. To improve the accuracy and reliability of fault diagnosis of T-connection transmission lines, a new method is proposed to identify specific faulty branches of T-connection transmission lines based on multi-scale traveling wave reactive power and random forest. Based on the S-transform, the mean and sum ratios of the corresponding short-time series traveling wave reactive powers of each two traveling wave protection units at multiple frequencies are calculated respectively to form the fault feature vector sample set of the T-connection transmission line.
View Article and Find Full Text PDFPLoS One
March 2020
Artificial Intelligence Key Laboratory of Sichuan Province, Sichuan University of Science and Engineering, Zigong, China.
Due to the characteristics of T-connection transmission lines, a new method for T-connection transmission lines fault identification based on current reverse travelling wave multi-scale S-transformation energy entropy and limit learning machine is proposed. S-transform are implemented on the faulty reverse traveling waves measured by each traveling wave protection unit of the T-connection transmission line, the reverse travelling wave energy entropies under eight different frequencies are respectively calculated, and a T-connection transmission line fault characteristic vector sample set are thus formed. Establish an intelligent fault identification model of extreme learning machines, and use the sample set for training and testing to identify the specific faulty branch of the T-connection transmission line.