Fluorescence of D-Glucose-Derived Carbon Dots: Effect of Process Parameters.

J Fluoresc

Faculty of Chemical Engineering and Technology, Department of Chemical Technology and Environmental Analytics, Cracow University of Technology, Warszawska 24, 31-155, Cracow, Poland.

Published: July 2024

The aim of this study was to synthesize highly fluorescent carbon dots (CDs) from glucose using a microwave hydrothermal method. It explored the impact of glucose concentration, process time, molar ratio of KHPO to glucose, and homogenization time on the resulting CDs, employing a fractional plan 3 with four independent parameters for twenty-seven synthesis. Results showed that longer process times at 200°C increased the fluorescence intensity of the CDs. The molar ratio of KHPO to glucose, glucose concentration, and process time significantly influenced fluorescence. Homogenization was crucial for obtaining small particles, though an anti-aggregation agent might still be needed. UV-vis spectroscopy, spectrofluorimetry, and DLS were used to analyze the synthesized CDs. The UV-vis absorption maxima were observed around 230 nm and 282 nm, with peak shifts at different excitation wavelengths. Out of the twenty-seven samples, six CDs samples were identified to be below 10 nm and a total of twelve below 50 nm. Analyzing the results, the study concluded that the CDs possess strong fluorescence and are suitable for diverse applications. For enhanced fluorescence, longer process times at 200°C and the use of KHPO were recommended, while shorter processes were preferred for obtaining smaller particles. Hierarchical clustering, the k-means method, Pareto charts, and profiles for predicted values and desirability were used to analyze the results. It was confirmed that higher fluorescence is favored by longer process time at 200°C and the use of KHPO. In order to obtain smaller particles, shorter processes should be used.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249403PMC
http://dx.doi.org/10.1007/s10895-023-03392-zDOI Listing

Publication Analysis

Top Keywords

process time
12
longer process
12
carbon dots
8
glucose concentration
8
concentration process
8
molar ratio
8
ratio khpo
8
khpo glucose
8
process times
8
times 200°c
8

Similar Publications

Importance: An increasing number of older adults are undergoing surgery. Older adults face significant challenges throughout the spectrum of perioperative care. No frameworks exist to support primary care clinicians in helping older adults navigate perioperative care beyond preoperative medical clearance.

View Article and Find Full Text PDF

Automated High-Throughput Affinity Capture-Mass Spectrometry Platform with Data-Independent Acquisition.

J Proteome Res

January 2025

Discovery Research, AbbVie, Inc., 1 North Waukegan Rd., North Chicago, Illinois 60064, United States.

Affinity capture (AC) combined with mass spectrometry (MS)-based proteomics is highly utilized throughout the drug discovery pipeline to determine small-molecule target selectivity and engagement. However, the tedious sample preparation steps and time-consuming MS acquisition process have limited its use in a high-throughput format. Here, we report an automated workflow employing biotinylated probes and streptavidin magnetic beads for small-molecule target enrichment in the 96-well plate format, ending with direct sampling from EvoSep Solid Phase Extraction tips for liquid chromatography (LC)-tandem mass spectrometry (MS/MS) analysis.

View Article and Find Full Text PDF

Current approaches for classifying biosensor data in diagnostics rely on fixed decision thresholds based on receiver operating characteristic (ROC) curves, which can be limited in accuracy for complex and variable signals. To address these limitations, we developed a framework that facilitates the application of machine learning (ML) to diagnostic data for the binary classification of clinical samples, when using real-time electrochemical measurements. The framework was applied to a real-time multimeric aptamer assay (RT-MAp) that captures single-frequency (12.

View Article and Find Full Text PDF

Purpose: Involving patients in developing patient-reported outcome measures (PROMs) is essential for accurately capturing their perspectives. However, understanding how patients were involved in developing PROMs used after hip or knee arthroplasty is limited. This scoping review aimed to evaluate whether patients were involved in the development of these PROMs and how they were involved.

View Article and Find Full Text PDF

Integrated analysis of marked and count data to characterize fine-scale stream fish movement.

Oecologia

January 2025

Department of Fish, Wildlife, and Conservation Biology, Colorado State University, Fort Collins, CO, 80523, USA.

Immigration and emigration are key demographic processes of animal population dynamics. However, we have limited knowledge on how fine-scale movement varies over space and time. We developed a Bayesian integrated population model using individual mark-recapture and count data to characterize fine-scale movement of stream fish at 20-m resolution in a 740-m study area every two months for 28 months.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!