AI Article Synopsis

  • The study aimed to compare biopsy recommendation rates and accuracy between the Prostate Imaging-Reporting and Data System version 2 (PI-RADSv2) and the Likert scale for detecting significant and insignificant prostate cancer in men aged 50-69 participating in the IP1-PROSTAGRAM trial.
  • Men were screened using Prostagram MRI, and results showed that more patients were recommended for biopsy with the Likert scale compared to PI-RADSv2 when the MRI score was ≥3, though accuracy in detecting cancer was similar for both systems.
  • The findings indicate that while the Likert scale may suggest more biopsy recommendations, both methods have comparable effectiveness in identifying clinically significant prostate cancer.

Article Abstract

Objective: To compare biopsy recommendation rates and accuracy of the Prostate Imaging-Reporting and Data System, version 2 (PI-RADSv2) with the Likert scale for detection of clinically significant and insignificant prostate cancer in men screened within the Imperial Prostate 1 Prostate Cancer Screening Trial Using Imaging (IP1-PROSTAGRAM).

Patients And Methods: Men aged 50-69 years were screened with Prostagram MRI. Scans were prospectively reported using both PI-RADSv2 (excluding dynamic contrast-enhanced sequence score) and 5-point Likert scores by expert uro-radiologists. Systematic and targeted transperineal biopsy was recommended if the scan was scored ≥ 3, based on either reporting system. The proportion of patients recommended for biopsy and detection rates for Grade Groups (GGs) 1 and ≥ 2 were compared. Receiver operating characteristic (ROC) analysis was performed to compare performance.

Results: A total of 406 men underwent Prostagram MRI. The median (interquartile range) age and prostate-specific antigen level were 57 (53-61) years and 0.91 (0.56-1.74) ng/mL, respectively. At MRI score ≥ 3, more patients were recommended for biopsy based on Likert criteria (94/406; 23%, 95% confidence interval [CI] 19.2%-27.6%) compared to PI-RADSv2 (72/406; 18%, 95% CI 14.2%-21.9%; P = 0.03). For MRI scores ≥ 4, PI-RADSv2 and Likert scales led to 43/406 (11%, 95% CI 7.9%-14.1%) and 35/406 (9%, 95% CI 6.2%-11.9%) men recommended for biopsy (P = 0.40). For GG ≥ 2 detection, PIRADSv2 and Likert detected 22% (95% CI 11.4%-30.8%, 14/72) and 16% (95% CI 9.5%-25.3%, 15/94), respectively (P = 0.56). For GG1 cancers detection these were 11% (95% CI 4.3%-19.6%, seven of 72) vs 11% (95% CI 4.7%-17.8%, nine of 94; P = 1.00). The accuracy of PI-RADSv2 and Likert scale was similar (area under the ROC curve 0.64 vs 0.65, P = 0.95).

Conclusions: In reporting non-contrast-enhanced Prostagram MRI in a screening population, the PI-RADSv2 and Likert scoring systems were equally accurate; however, Likert scale use led to more men undergoing biopsy without a subsequent increase in significant cancer detection rates. To improve reporting of Prostagram MRI, either the PI-RADSv2 or a modified Likert scale or a standalone scoring system should be developed.

Download full-text PDF

Source
http://dx.doi.org/10.1111/bju.16155DOI Listing

Publication Analysis

Top Keywords

pi-radsv2 likert
16
likert scale
16
prostagram mri
16
recommended biopsy
12
11% 95%
12
likert
9
screening population
8
prostate imaging-reporting
8
imaging-reporting data
8
data system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!