A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Deep learning-based fluorescence image correction for high spatial resolution precise dosimetry. | LitMetric

Deep learning-based fluorescence image correction for high spatial resolution precise dosimetry.

Phys Med Biol

Department of Radiation Oncology, Stanford University, Stanford, CA 94305-5847, United States of America.

Published: September 2023

While radiation-excited fluorescence imaging has great potential to measure absolute 2D dose distributions with high spatial resolution, the fluorescence images are contaminated by noise or artifacts due to Cherenkov light, scattered light or background noise. This study developed a novel deep learning-based model to correct the fluorescence images for accurate dosimetric application.181 single-aperture static photon beams were delivered to an acrylic tank containing quinine hemisulfate water solution. The emitted radiation-exited optical signals were detected by a complementary metal-oxide semiconductor camera to acquire fluorescence images with 0.3 × 0.3 mmpixel size. 2D labels of projected dose distributions were obtained by applying forward projection calculation of the 3D dose distributions calculated by a clinical treatment planning system. To calibrate the projected dose distributions for Cherenkov angular dependency, a novel empirical Cherenkov emission calibration method was performed. Total 400-epoch supervised learning was applied to a convolutional neural network (CNN) model to predict the projected dose distributions from fluorescence images, gantry, and collimator angles. Accuracy of the calculated projected dose distributions was evaluated with that of uncorrected or conventional methods by using a few quantitative evaluation metrics.The projected dose distributions corrected by the empirical Cherenkov emission calibration represented more accurate noise-free images than the uncalibrated distributions. The proposed CNN model provided accurate projected dose distributions. The mean absolute error of the projected dose distributions was improved from 2.02 to 0.766 mm·Gy by the CNN model correction. Moreover, the CNN correction provided higher gamma index passing rates for three different threshold criteria than the conventional methods.The deep learning-based method improves the accuracy of dose distribution measurements. This technique will also be applied to optical signal denoising or Cherenkov light discrimination in other imaging modalities. This method will provide an accurate dose verification tool with high spatial resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/acf182DOI Listing

Publication Analysis

Top Keywords

dose distributions
36
projected dose
28
fluorescence images
16
deep learning-based
12
high spatial
12
spatial resolution
12
cnn model
12
dose
11
distributions
10
cherenkov light
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!