A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Efficacy of Dural Puncture Epidural Performed by 27-gauge Whitacre Needle in Labour Epidural Analgesia: Randomized Single-Blinded Controlled Study. | LitMetric

Objective: Dural puncture epidural technique is refinement of standard epidural technique. Its goal is to overcome drawbacks of standard epidural. We assessed whether dural puncture epidural technique performed by 27-gauge spinal needle would provide higher quality of labour epidural analgesia by using 10 mL epidural bolus of 0.125% bupivacaine. Additionally, the impact of dural puncture epidural on epidural analgesia onset, course of labour and occurrence of maternal side effects was examined.

Methods: We designed prospective, randomized, single-blind study. A total of 76 healthy nulliparous parturients were randomly allocated to dural puncture or standard epidural group. After identification of epidural space, spinal Whitacre needle was used for dural puncture. Intrathecal drug administration was omitted at that point. Both groups received a bolus of local anaesthetic mixture, followed by a continuous infusion of diluted local anaesthetic via epidural catheter. Pain was assessed by numeric pain rating scale. The number of top-ups and mode of delivery were recorded in both groups.

Results: After 10 minutes, there was a statistically significant difference in numeric pain rating scale ≤3 reported (=0.028), with 97.4% subjects in dural puncture epidural group achieving adequate analgesia after 10 minutes. There was no statistically significant difference in the number of additional boluses, time to delivery, Bromage scale achieved or maternal outcomes between groups.

Conclusion: Dural puncture epidural technique appears to be effective in providing faster onset of epidural analgesia. However, the need for additional boluses remains unchanged. It can be safely used in obstetrics, without deleterious effect on the course of labour.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10440478PMC
http://dx.doi.org/10.4274/TJAR.2023.221085DOI Listing

Publication Analysis

Top Keywords

dural puncture
32
puncture epidural
24
epidural
16
epidural analgesia
16
epidural technique
16
standard epidural
12
puncture
8
performed 27-gauge
8
whitacre needle
8
labour epidural
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!