Dose assessment on the lunar surface is important for future long-term crewed activity. In addition to the major radiation of energetic charged particles from galactic cosmic rays (GCRs), neutrons and gamma-rays are generated by nuclear interactions of space radiation with the Moon's surface materials, as well as natural radioactive nuclides. We obtained neutron and gamma-ray ambient dose distributions on the Moon using Geant4 Monte Carlo simulations combined with the Kaguya gamma-ray spectrometer measurement dataset from February 10 to May 28, 2009. The neutron and gamma-ray dose rates varied in the ranges of 58.7-71.5 mSv/year and 3.33-3.76 mSv/year, respectively, depending on the lunar geological features. The lunar neutron dose was high in the basalt-rich mare, where the iron- and titanium-rich regions are present, due to their large average atomic mass. As expected, the lunar gamma-ray dose map was similar to the distribution of natural radioactive elements (U, Th, and K), although the GCR-induced secondary gamma-ray dose was significant at ~ 3.4 mSv/year. The lunar secondary dose contribution resulted in an additional dose of 12-15% to the primary GCR particles. Global dose distributions on the lunar surface will help identify better locations for long-term stays and suggest radiation protection strategies for future crewed missions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427620PMC
http://dx.doi.org/10.1038/s41598-023-40405-0DOI Listing

Publication Analysis

Top Keywords

dose distributions
12
gamma-ray dose
12
dose
9
global dose
8
neutrons gamma-rays
8
lunar surface
8
natural radioactive
8
neutron gamma-ray
8
lunar
6
gamma-ray
5

Similar Publications

Twisted halide perovskite bilayers, a type of moiré material, show square moiré patterns with exciting optical properties. Atomic-scale structure analysis and its correlation with properties are difficult to achieve due to the extreme sensitivity of organic-inorganic halide perovskites to the illuminated electron beam in conventional/scanning transmission electron microscopy. Here, we developed a low-dose exit wave reconstruction methodology with a real-space resolution of one angstrom at ∼50 e/Å, which recovers the phase information on the moiré fringes in CHNHPbI (MAPbI) twisted perovskite bilayers at atomic scale, enabling detailed structural analysis of defects and corresponding strain distribution in such moiré materials.

View Article and Find Full Text PDF

Long-term effects of combined exposures to simulated microgravity and galactic cosmic radiation on the mouse lung: sex-specific epigenetic reprogramming.

Radiat Environ Biophys

January 2025

Department of Environmental Health Sciences, #820-11, Slot, Fay W. Boozman College of Public Health, University of Arkansas for Medical Sciences, 4301 W. Markham Str, Little Rock, AR, 72205, USA.

Most studies on the effects of galactic cosmic rays (GCR) have relied on terrestrial irradiation using spatially homogeneous dose distributions of mono-energetic beams comprised of one ion species. Here, we exposed mice to novel beams that more closely mimic GCR, namely, comprising poly-energetic ions of multiple species. Six-month-old male and female C57BL/6J mice were exposed to 0 Gy, 0.

View Article and Find Full Text PDF

In this study, we investigated the cytotoxic effect of highly soluble dextran-coated CeO nanoparticles on human fetal lung fibroblasts MRC-5. We examined individual nanoparticle-treated cells by Raman spectroscopy and analyzed Raman spectra using non-negative principal component analysis and k-means clustering. In this way, we determined dose-dependent differences between treated cells, which were reflected through the intensity change of lipid, phospholipid and RNA-related Raman modes.

View Article and Find Full Text PDF

Purpose: To evaluate the impact of patient setup errors on the dosimetry and radiobiological models of intensity-modulated radiotherapy (IMRT) for esophageal cancer.

Methods And Materials: This retrospective study with 56 patients in thermoplastic mask (TM) and vacuum bag (VB) groups utilized real setup-error (RSE) data from cone-beam CT scans to generate simulated setup-error (SSE) data following a normal distribution. The SSE data were applied to simulate all treatment fractions per patient by shifting the plan isocenter and recalculating the dose.

View Article and Find Full Text PDF

Background And Purpose: In proton therapy, a relative biological effectiveness (RBE) of 1.1 is used to convert proton dose into an equivalent photon dose. However, RBE varies with tissue type, fraction dose, and beam quality parameters beyond dose such as linear energy transfer (LET) raising concerns about increased local effectiveness and potential toxicity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!