Background: Tricuspid regurgitation (TR) is a common and progressive valve disease with significant mortality and hospitalization burden. Tricuspid transcatheter edge-to-edge repair provides a treatment option for high-risk patients with primary and secondary TR.

Methods: The TRILUMINATE trial ([Trial to Evaluate Treatment With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater Tricuspid Regurgitation]; n=85) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of tricuspid transcatheter edge-to-edge repair with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessment was performed at a core laboratory. Outcomes included safety and clinical effectiveness and echocardiographic assessment of TR.

Results: At 2 years, TR was reduced to moderate or less in 60% of subjects, and reduction of at least 1 grade was achieved in 85.4% of subjects. TR reduction was sustained in 75% of the patients. While most metrics suggest the majority of favorable remodeling occurred within the first 30 days post-procedure, both right ventricular end diastolic diameter and tricuspid annular plane systolic excursion show signals of continued favorable remodeling through 2 years. Substantial improvements in 6-minute walking distance, New York Heart Association functional class, and Kansas City Cardiomyopathy Questionnaire score were sustained from 30 days to 2 years. Even with low rates of cardiovascular mortality (15.3%) and all-cause mortality (18.7%) noted at 2 years, all-cause hospitalization rate decreased from 1.30 events per patient-year 1 year before device implantation to 0.66 events per patient-year 2 years after the TriClip procedure, representing a reduction of 49% (<0.0001).

Conclusions: Tricuspid transcatheter edge-to-edge repair using the TriClip implant was found to be safe and effective, with sustained benefits at 2 years in subjects with symptomatic moderate or greater TR. Repair efficacy was durable at 2 years in 75% of the patients.

Registration: URL: https://www.

Clinicaltrials: gov; Unique identifier: NCT03227757.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.122.012888DOI Listing

Publication Analysis

Top Keywords

transcatheter edge-to-edge
12
triluminate trial
8
tricuspid transcatheter
8
edge-to-edge repair
8
moderate greater
8
echocardiographic assessment
8
subjects reduction
8
favorable remodeling
8
events patient-year
8
tricuspid
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!