[Structural Design and Penumbra Analysis of Dynamic Multi-leaf Collimator Leaf End].

Zhongguo Yi Liao Qi Xie Za Zhi

SuperAccuracy Science & Technology Co. Ltd., Nanjing, 210044.

Published: July 2023

Dynamic multi-leaf collimator, which has the function of radiation beam shaping, is a key executive component of tumor precise radiotherapy, and plays a core role in improving the accuracy, efficiency and quality of radiotherapy. A new type of collimator leaf end structure with circular arc and plane combination was studied, and collimator penumbra performance analysis model combining analytical expression and graphic analysis was developed. The influence of leaf end structure on penumbra was analyzed quantitatively, and a set of three-dimensional structure design of dynamic multi-leaf collimator was completed. The feasibility of the structural design and analysis model was verified through experimental measurements.

Download full-text PDF

Source
http://dx.doi.org/10.3969/j.issn.1671-7104.2023.04.005DOI Listing

Publication Analysis

Top Keywords

dynamic multi-leaf
12
multi-leaf collimator
12
collimator leaf
8
leaf structure
8
analysis model
8
collimator
5
[structural design
4
design penumbra
4
analysis
4
penumbra analysis
4

Similar Publications

Design and performance of a novel multi-leaf collimator composed of leaves with fixed and movable layers.

Med Phys

November 2024

Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: The multi-leaf collimator (MLC) is an advanced device utilized for beam shaping and intensity modulation in radiotherapy. With the framework of the contemporary single-layer MLC featuring a rounded leaf tip, the leaf tip transmission and leakage exert a considerable influence on radiotherapy.

Purpose: To scale down the leakage and transmission from the leaf gap when the opposite leaves are closed.

View Article and Find Full Text PDF

Introduction Volumetric-modulated arcs (VMA) can produce dose distributions suitable for stereotactic radiosurgery (SRS) with a multi-leaf collimator (MLC) for brain metastases (BMs). The treatment planning and verification for VMA are more complicated than for dynamic conformal arcs. The longer the preparation time from image acquisition to the start of irradiation, the higher the risk of tumor growth and/or displacement.

View Article and Find Full Text PDF
Article Synopsis
  • This study focuses on validating beam data from three beam-matched linear accelerators (LAs) for accurate radiation delivery in fractionated stereotactic treatment, comparing measured data to vendor reference data.
  • Measurements included percentage depth dose, beam profiles, output factors, and dynamic multi-leaf collimator factors for different photon types, achieving high accuracy with gamma analysis above 97%.
  • Quality assurance for eighty patient-specific plans showed median passing rates of over 76% to 98% across various gamma criteria, indicating compatibility of treatment across the beam-matched LAs without the need for re-planning.
View Article and Find Full Text PDF

Aim: This study aimed to evaluate the efficacy of static or step-and-shoot intensity-modulated radiotherapy (ssIMRT) and dynamic intensity-modulated radiotherapy (dIMRT) delivery techniques for various treatment sites.

Materials And Methods: The treatment planning system (TPS) was utilized to develop optimal treatment plans for twenty-seven patients selected for this comparative study, including nine with head and neck cancer, nine with prostate cancer, and nine with cervical cancer. The prescribed doses were 7000cGy/33fr, 7425cGy/33fr, and 5000cGy/25fr for the nasopharynx, prostate, and cervix cases, respectively, in both ssIMRT and dIMRT delivery techniques.

View Article and Find Full Text PDF

Generating 3D images of VMAT plans for predictive models and activation maps associated with plan deliverability.

Med Phys

October 2024

Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.

Background: Intensity modulation with dynamic multi-leaf collimator (MLC) and monitor unit (MU) changes across control points (CPs) characterizes volumetric modulated arc therapy (VMAT). The increased uncertainty in plan deliverability required patient-specific quality assurance (PSQA), which remained inefficient upon Quality Assurance (QA) failure. To prevent waste before QA, plan complexity metrics (PCMs) and machine learning models with the metrics were generated, which were lack of providing CP-specific information upon QA failures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!