[Progress in Development of Dose Verification System Software KylinRay-Dose4D].

Zhongguo Yi Liao Qi Xie Za Zhi

SuperAccuracy Science & Technology Co. Ltd., Nanjing, 210044.

Published: July 2023

Advanced radiotherapy technology enables the dose to more accurately conform to the tumor target area of the patient, providing accurate treatment for the patient, but the gradient of the patient's radiation dose at the tumor edge is getting larger, which putting forward higher requirements for radiotherapy dose verification. The dose verification system software KylinRay-Dose4D can verify the patient's pre-treatment plan and the /on-line dose during the patient's treatment, providing important reference for the physicist to modify the radiotherapy plan and ensuring that the patient receives accurate treatment. This study introduces the overall design and key technologies of KylinRay-Dose4D, and tests the pre-treatment plan dose checking calculation and 2D/3D dose verification through clinical cases. The test results showed that the 2D/3D gamma pass rate (3 mm/3%) of KylinRay-Dose4D reconstructed dose compared with TPS plan dose and measured dose is larger than 95%, which indicating that the reconstructed dose of KylinRay-Dose4D meets the requirement of clinical application.

Download full-text PDF

Source
http://dx.doi.org/10.3969/j.issn.1671-7104.2023.04.002DOI Listing

Publication Analysis

Top Keywords

dose verification
16
dose
12
verification system
8
system software
8
accurate treatment
8
pre-treatment plan
8
plan dose
8
reconstructed dose
8
[progress development
4
development dose
4

Similar Publications

Background: This study investigates the impact of convergence mode (CM) in Eclipse (Varian Medical Systems) on the quality and complexity of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC) patients.

Methods: We retrospectively analyzed data from 21 NPC patients. For each patient, three VMAT plans with different CM settings (Off, On, and Extended) were created using identical optimization objectives.

View Article and Find Full Text PDF

Background: Conventional approaches for emergent or expedited palliative radiotherapy (RT) involve the application of cumbersome vendor-provided solutions and/or multiple patient appointments to complete the RT workflow within a compressed timeframe.

Purpose: This report delineates the clinical development of an in-house, semi-automated Cone-beam computed tomography (CBCT)-based simulation-free platform for expedited palliative RT on conventional linacs, intended to supplant existing techniques employed at this institution.

Methods: The internal software, termed SimFree Wizard (SFW), was engineered utilizing a C#-based application programming interface integrated within the treatment planning system (TPS).

View Article and Find Full Text PDF

A gamma cell unit is used for gamma irradiation of small volume samples. Due to the sample volume, there is a dose distribution, which is imperative to be known for appropriate irradiation. In this study, samples of agarose Fricke gel dosimeters were prepared for the dose mapping of the gamma cell unit available in our laboratory.

View Article and Find Full Text PDF

Using artificial intelligence (AI) to enhance chimeric antigen receptor (CAR)-based therapies' design, production, and delivery is a novel and promising approach. This review provides an overview of the current applications and challenges of AI for CAR-based therapies and suggests some directions for future research and development. This paper examines some of the recent advances of AI for CAR-based therapies, for example, using deep learning (DL) to design CARs that target multiple antigens and avoid antigen escape; using natural language processing to extract relevant information from clinical reports and literature; using computer vision to analyze the morphology and phenotype of CAR cells; using reinforcement learning to optimize the dose and schedule of CAR infusion; and using AI to predict the efficacy and toxicity of CAR-based therapies.

View Article and Find Full Text PDF

Background And Purpose: Although carbon-ion radiotherapy (CIRT) has led to good outcomes, controlling metastasis is still crucial for improving overall survival. This study aimed to evaluate the effectiveness of by two combinations, one of CIRT and anti-CTLA4 antibody, the other of CIRT and anti-PD-1 antibody, applied at different radiation doses for distal tumour and metastasis suppression.

Materials And Methods: Murine cancer cells (colon carcinoma Colon-26 cells for experiments and osteosarcoma LM8 cells for verification) were grafted into both sides of the hind legs of syngeneic mice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!