Instantaneous and time-averaged intensity flow measurements in scale models.

JASA Express Lett

Graduate Program in Architectural Acoustics, Rensselaer Polytechnic Institute, Troy, New York 12180,

Published: August 2023

Current methods of representing energy flows in rooms have been limited to stationary pressure contour maps or intensity vectors derived from finite-element modeling (FEM) software. Despite recent advances in FEM analysis, such models are at best approximations of real-world phenomena because of the assumptions made in obtaining these results. This paper presents an energy flow visualization tool that combines the well-accepted practice of scale modeling in performance venue acoustics design and recent advances in sensor technology to provide rapid and accurate real-time maps of intensity flows derived from simultaneously-measured pressure and velocity quantities in the studied space.

Download full-text PDF

Source
http://dx.doi.org/10.1121/10.0020647DOI Listing

Publication Analysis

Top Keywords

maps intensity
8
instantaneous time-averaged
4
time-averaged intensity
4
intensity flow
4
flow measurements
4
measurements scale
4
scale models
4
models current
4
current methods
4
methods representing
4

Similar Publications

This study advances the state of the art by computing the macroscopic elastic properties of 2D periodic functionally graded microcellular materials, incorporating both isotropic and orthotropic solid phases, as seen in additively manufactured components. This is achieved through numerical homogenization and several novel MATLAB implementations (known in this study as , , , and ). The developed codes in the current work treat each cell as a material point, compute the corresponding cell elasticity tensor using numerical homogenization, and assign it to that specific point.

View Article and Find Full Text PDF

Purpose: The long scan times of quantitative MRI techniques make motion artifacts more likely. For MR-Fingerprinting-like approaches, this problem can be addressed with self-navigated retrospective motion correction based on reconstructions in a singular value decomposition (SVD) subspace. However, the SVD promotes high signal intensity in all tissues, which limits the contrast between tissue types and ultimately reduces the accuracy of registration.

View Article and Find Full Text PDF

Accurate DNA Sequence Prediction for Sorting Target-Chirality Carbon Nanotubes and Manipulating Their Functionalities.

ACS Nano

January 2025

South China Advanced Institute for Soft Matter Science and Technology, School of Emergent Soft Matter, South China University of Technology, Guangzhou 510640, China.

Synthetic single-wall carbon nanotubes (SWCNTs) contain various chiralities, which can be sorted by DNA. However, finding DNA sequences for this purpose mainly relies on trial-and-error methods. Predicting the right DNA sequences to sort SWCNTs remains a substantial challenge.

View Article and Find Full Text PDF

The data presented here are the result of microtremor measurements at 44 points in three different soil types classified according to their fundamental vibration frequencies, on the metropolitan area of Veracruz-Boca del Río, Mexico. These Data are raw and was obtained using a GÜRALP 6TD model broadband orthogonal triaxial seismometer with an integrated 24-bit digitizer with a minimum recording time of 30 min and a recording rate of 100 samples per second (sps). The microtremor records were used to construct the H/V spectral ratios using the method of Nakamura.

View Article and Find Full Text PDF

A preliminary study was conducted using electronic portal imaging device (EPID) based dose verification in pre-treatment and in vivo dose reconstruction modes for breast cancer intensity-modulated radiation therapy (IMRT) technique with known repositioning set-up errors. For 43 IMRT plans, the set-up errors were determined from 43 sets of EPID images and 258 sets of cone beam computed tomography images. In-house developed Edose software was used to reconstruct the dose distribution using the pre-treatment and on-treatment (in vivo) EPID acquired fluence maps.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!