Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: For infants requiring intensive care, infant length is a primary gauge of nutrition and forms the basis for important future treatment decisions. However, existing evidence demonstrates discrepancies in infant length measurements between tape measure and length board.
Purpose: To compare the accuracy and reliability of infant length measurements using tape measure (standard practice) and length board in a neonatal intensive care unit (NICU) at a public academic medical center.
Methods: Using a single-group, quasi-experimental, repeated-measures design, 108 infants (35.58 ± 3.68 weeks, male 59%, 2124.83 ± 881.69 g) admitted to the NICU were prospectively enrolled. Clinical nurses measured infants weekly per unit-based protocol using tape measures. Study team measured length using length boards within 24 hours of tape measurement. Primary outcome was infant length. Length measurements were converted to sex-specific Fenton or WHO growth percentiles. Linear mixed-effects regression, κ coefficient, intraclass correlation coefficient, and positive predictive value were calculated.
Findings/results: The main effect of measurement conditions and time was significant. Predicted length was 0.38 cm lower for length board than for tape measure over time. Weighted κ coefficient and intraclass correlation coefficient indicated good to excellent agreement. More than 37% of infants shifted to a new percentile category based on both measurements. Positive predictive value of length board at time 1 was 63%.
Implications For Practice: Length board measurements are reliable for accurate classification of an infant's growth curve to influence diagnosis and future plan of care.
Implications For Research: Future research warrants replication using a longitudinal design across multiple sites.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ANC.0000000000001098 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!