The chimney endovascular aneurysm repair (Ch-EVAR) technique has progressively increased in popularity in the treatment of complex aortic aneurysms. However, the long-term results of this technique still must be assessed, especially in comparison to custom-made solutions. The patency of chimney grafts has always been one of the important issues with the Ch-EVAR technique. However, interactions between nonstented aortic side branches and chimney stent grafts have rarely been discussed. In the present case report, we describe a rare case of mesenteric ischemia due to superior mesenteric artery ostium coverage by the misalignment of a renal stent graft in a Ch-EVAR.