Background: Left atrial appendage closure (LAAC) is a mechanical alternative for stroke prevention in patients at risk who cannot tolerate oral anticoagulation (OAC).

Hypothesis: Our hypothesis was that the reduction of anticoagulation following LAAC results in a decrease of bleeding events and a rise in serum hemoglobin in a high-risk collective of patients with atrial fibrillation (AF).

Methods: Bleeding events, use of erythrocyte concentrates, anticoagulation, embolic events, and serum hemoglobin levels before and following LAAC were compared over more than 4 years.

Results: Seventy-five patients (CHA₂DS₂-VASc score 4.4 ± 1.7, HAS-BLED score 4.6 ± 1.1) were analyzed. Before LAAC (observation period 1.8 ± 1.8 years), 67 patients experienced 1.8 ± 1.4 bleeding events (0.9 ± 1.3 major) per year resulting in 0.7 ± 1.3 transfusions per year. After LAAC (2.6 ± 2.0 years), 26 patients (p < .0001 vs. before) had 0.6 ± 2.1 bleeding events (p < .0001), 0.2 ± 0.6 major bleedings (p < .0001) and received 0.6 ± 1.9 transfusions per year (p = .671). Fourteen patients had stroke before and 3 after LAAC (p = .008). Serum hemoglobin increased from initially 9.9 ± 3.0 to 11.9 ± 2.3 g/dL until the end of follow-up (p = .0005). Adverse embolic events did not differ before and after LAAC in our collective.

Conclusion: In this clinical relevant cohort of AF patients with high risk for stroke and intolerance to OAC, we show that LAAC was able to reduce the rate of stroke and bleeding events, which translated into a rising serum hemoglobin concentration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642336PMC
http://dx.doi.org/10.1002/clc.24123DOI Listing

Publication Analysis

Top Keywords

bleeding events
12
left atrial
8
atrial appendage
8
appendage closure
8
serum hemoglobin
8
years patients
8
patients
6
laac
5
major bleeding
4
bleeding higher
4

Similar Publications

: The parallel stent graft endovascular aortic repair (PGEVAR) technique is an off-the-shelf option used for elective complex abdominal aortic aneurysm repair with acceptable outcome results, as reported so far. The PGEVAR technique, using chimney or periscope parallel grafts, can also be used for patients with ruptured complex abdominal aortic aneurysms. However, only few data about the mid- to long-term outcomes are available.

View Article and Find Full Text PDF

: Direct oral anticoagulants (DOACs) are frequently used to prevent embolism in atrial fibrillation. Gastrointestinal bleeding is frequent, but its drug-specific characteristics remain unclear. This study examined the frequency and characteristics of gastrointestinal bleeding in patients with nonvalvular atrial fibrillation for different DOACs.

View Article and Find Full Text PDF

: Significant intraoperative and postoperative blood loss are rare but possibly life-threatening complications after lung resection surgery either during open or minimally invasive procedures. Microporous Polysaccharide Haemospheres (ARISTA™AH) have demonstrated time-efficient haemostasis, lower postoperative blood volumes and a lower blood transfusion requirement, without any identified adverse events across other specialities. The primary aim of our study was to evaluate the impact of ARISTA™AH on short-term postoperative outcomes in thoracic surgery.

View Article and Find Full Text PDF

Despite the high progress that has been made in the field of cardiology, the left ventricular assist device (LVAD) can still cause complications (thrombosis/bleeding) in heart failure (HF) patients after implantation. Complications develop due to the incorrect dose of antithrombotic therapy, due to the influence of the non-physiological shear stress of the device, and also due to inherited genetic polymorphisms. Therefore, the aim of our study is to identify the influence of the genetic polymorphisms on complication development in HF patients with implanted LVADs with prescribed antiplatelet therapy.

View Article and Find Full Text PDF

WATCHMAN versus LACbes® device for percutaneous left atrial appendage closure: a single-center, propensity-matched study.

BMC Cardiovasc Disord

January 2025

Department of Cardiology, Changhai Hospital, Naval Medical University, No. 168 Changhai Road, Yangpu District, Shanghai, 200433, China.

Background: Different left atrial appendage closure (LAAC) devices have been introduced into the clinical setting. A new dual-seal mechanism LACbes® occluder with isogenous barbs for LAAC has been designed to facilitate easier delivery and improve safety. The purpose of this study is to compare the clinical outcomes of the WATCHMAN with those of the LACbes® device for LAAC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!