A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flexible BaTiO-PDMS Capacitive Pressure Sensor of High Sensitivity with Gradient Micro-Structure by Laser Engraving and Molding. | LitMetric

The significant potential of flexible sensors in various fields such as human health, soft robotics, human-machine interaction, and electronic skin has garnered considerable attention. Capacitive pressure sensor is popular given their mechanical flexibility, high sensitivity, and signal stability. Enhancing the performance of capacitive sensors can be achieved through the utilization of gradient structures and high dielectric constant media. This study introduced a novel dielectric layer, employing the BaTiO-PDMS material with a gradient micro-cones architecture (GMCA). The capacitive sensor was constructed by incorporating a dielectric layer GMCA, which was fabricated using laser engraved acrylic (PMMA) molds and flexible copper-foil/polyimide-tape electrodes. To examine its functionality, the prepared sensor was subjected to a pressure range of 0-50 KPa. Consequently, this sensor exhibited a remarkable sensitivity of up to 1.69 KPa within the pressure range of 0-50 KPa, while maintaining high pressure-resolution across the entire pressure spectrum. Additionally, the pressure sensor demonstrated a rapid response time of 50 ms, low hysteresis of 0.81%, recovery time of 160 ms, and excellent cycling stability over 1000 cycles. The findings indicated that the GMCA pressure sensor, which utilized a gradient structure and BaTiO-PDMS material, exhibited notable sensitivity and a broad linear pressure range. These results underscore the adaptability and viability of this technology, thereby facilitating enhanced flexibility in pressure sensors and fostering advancements in laser manufacturing and flexible devices for a wider array of potential applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10422564PMC
http://dx.doi.org/10.3390/polym15153292DOI Listing

Publication Analysis

Top Keywords

pressure sensor
16
pressure range
12
pressure
9
capacitive pressure
8
high sensitivity
8
dielectric layer
8
batio-pdms material
8
range 0-50
8
0-50 kpa
8
sensor
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!