Seafood elemental profiling (SEP) is the quantification of a range of elements in seafood products and may serve in addressing questions of seafood provenance and quality. Traditional methods for analyzing soft tissue present several limitations for the industry-level use of SEP. Portable handheld X-ray fluorescence (pXRF) analysis is a promising alternative to conventional methods; however, its application for biological analysis has not been fully established. Intact giant tiger prawn () abdomens were analyzed with a Vanta M series XRF portable analyzer following a novel soft tissue protocol. Exploratory statistics (principal component analysis, nonmetric multidimensional scaling, and canonical discriminant analysis), as well as random forest models, have been implemented with pXRF profiles, yielding 81% accuracy when assigning the geographical origin of . The results of this study highlight that SEP via pXRF is a viable industry-level analysis, and its application will depend on improved instrument calibration to account for fluctuating wetness factors that are influenced by cooking, storage, and other pre- and post-harvest treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10417198PMC
http://dx.doi.org/10.3390/foods12152874DOI Listing

Publication Analysis

Top Keywords

portable handheld
8
handheld x-ray
8
x-ray fluorescence
8
seafood provenance
8
soft tissue
8
analysis
5
evaluating application
4
application portable
4
fluorescence xrf
4
xrf scanner
4

Similar Publications

Thorough consideration of user experiences and the weighing of advantages and disadvantages are essential when implementing new technology in clinical practice. This article describes a primary care nurse's experience using two technologies to monitor lung congestion in six patient cases: a remote dielectric sensing device for non-invasive lung fluid measurement and a portable handheld ultrasound device. Both can support decision-making when assessing lung congestion in heart failure patients.

View Article and Find Full Text PDF

A handheld biofluorometric system for acetone detection in exhaled breath condensates.

Analyst

January 2025

Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.

As a marker of human metabolism, acetone is important for lipid metabolism monitoring and early detection of diabetes. In this study, we developed a handheld biosensor for acetone based on fluorescence detection by utilizing the enzymatic reaction of secondary alcohol dehydrogenase (S-ADH) with β-nicotinamide adenine dinucleotide (NADH, = 340 nm, = 490 nm). In the reaction, NADH is oxidized when acetone is reduced to 2-propanol by S-ADH, and the acetone concentration can be measured by detecting the amount of NADH consumed in this reaction.

View Article and Find Full Text PDF

Postpartum urinary retention has a wide range of publicized incidences, likely caused by frequent misdiagnosis of this puerperal complication. Especially covert postpartum urinary retention has a high number of missed diagnoses due to the lack of symptoms and the time-extensive diagnostics via ultrasound, leading to no treatment and no appropriate follow-up. To simplify the diagnosis and establish a screening tool we analyzed the application of portable handheld-ultrasound devices  (PUD) as used in Point-of-care diagnostics in comparison to established standard ultrasound devices (SUD).

View Article and Find Full Text PDF

Diazepam (DZP) is a muscle-relaxing, anxiety-relieving sedative drug; nonetheless, it is also an addictive drug that may be abused. This work reports on the development of a novel electrochemical nanosensor for diazepam using SiO-encapsulated-3-mercaptopropionic acid-capped AuZnCeSeS quantum dots (QDs) overcoated with a molecularly imprinted polymer (MIP) on screen-printed carbon electrodes (SPCEs). Electrochemical, spectroscopic and electron microscopic characterization of the nanomaterial and modified electrode surface was carried out and is reported herein.

View Article and Find Full Text PDF

Background: Numerous studies have explored image processing techniques aimed at enhancing ultrasound images to narrow the performance gap between low-quality portable devices and high-end ultrasound equipment. These investigations often use registered image pairs created by modifying the same image through methods like down sampling or adding noise, rather than using separate images from different machines. Additionally, they rely on organ-specific features, limiting the models' generalizability across various imaging conditions and devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!