Background: To verify whether the severity of coronary stenosis could be non-invasively assessed by enhanced transthoracic coronary echo Doppler in convergent color Doppler mode (E-Doppler TTE) over a wide range of values (from mild to severe).

Methods: Color-guided pulsed wave Doppler sampling in the left anterior descending coronary artery (LAD) was performed in 103 diseased LAD segments (corresponding to 94 patients examined) as assessed by quantitative coronary angiography (QCA) or intracoronary ultrasound (IVUS). The E-Doppler TTE examinations consisted of measuring the velocity (vel) at the stenosis site and a reference adjacent segment. Then the continuity equation (C-Eq) was applied to calculate the percent cross-sectional area reduction (%CSA) at the stenosis site. The applied formula was: %CSA = 100 × (1 - [TVIref × 0.5]/TVIs). TVI = the time velocity integral at the stenosis [s] and the reference site [ref], respectively); 0.5 = the correcting factor for a parabolic profile was used only when the % accelerated stenotic flow was >122% (AsF = diastolic peak vel at first site - diastolic peak vel at second site/diastolic peak vel at second site × 100).

Results: E-Doppler TTE feasibility was 100%. Doppler and QCA/IVUS-derived %CSA stenosis showed very good agreement over a large range of values (from mild to severe), with no significant bias; the maximum difference between QCA/IVUS and transthoracic Doppler %CSA was mostly around 20% with a few patients exceeding this limit (limits of agreement = -27.53 to 23.5%). The scattering was slightly larger for the non-significant stenoses. The correlation was strong (r = 0.89, < 0.001).

Conclusion: E-Doppler TTE is a feasible and reliable method for assessing the severity of LAD stenosis by applying the C-Eq.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10417389PMC
http://dx.doi.org/10.3390/diagnostics13152526DOI Listing

Publication Analysis

Top Keywords

e-doppler tte
16
peak vel
12
left anterior
8
anterior descending
8
descending coronary
8
coronary artery
8
enhanced transthoracic
8
transthoracic doppler
8
continuity equation
8
range values
8

Similar Publications

Background: Accelerated stenotic flow (AsF) in the entire left anterior descending coronary artery (LAD), assessed by transthoracic enhanced color Doppler (E-Doppler TTE), can reveal coronary stenosis (CS) and its severity, enabling a distinction between the microcirculatory and epicardial causes of coronary flow reserve (CFR) impairment.

Methods: Eighty-four consecutive patients with a CFR <2.0 (1.

View Article and Find Full Text PDF

Background: To verify whether the severity of coronary stenosis could be non-invasively assessed by enhanced transthoracic coronary echo Doppler in convergent color Doppler mode (E-Doppler TTE) over a wide range of values (from mild to severe).

Methods: Color-guided pulsed wave Doppler sampling in the left anterior descending coronary artery (LAD) was performed in 103 diseased LAD segments (corresponding to 94 patients examined) as assessed by quantitative coronary angiography (QCA) or intracoronary ultrasound (IVUS). The E-Doppler TTE examinations consisted of measuring the velocity (vel) at the stenosis site and a reference adjacent segment.

View Article and Find Full Text PDF

: Coronary blood flow Doppler recording by Transthoracic Doppler in convergent mode (E-Doppler TTE) might be further improved by lowering heart rate (HRL) down to <60 bpm, since low HR < 60 b/m causes a disproportional lengthening of the diastole, so the coronaries are still for a longer time, very much improving the Doppler signal/noise ratio. : A group of 26 patients underwent E-Doppler TTE before and after HR lowering in four branches of the coronary tree, namely, the left main (LMCA); left anterior descending (LAD), subdivided into three segments: proximal, mid and distal; proximal left circumflex (LCx); and obtuse marginal (OM). Color and PW coronary Doppler signal was judged by two expert observers as undetectable (SCORE 1), weak or with clutter artifacts (SCORE 2), or well delineated (SCORE 3).

View Article and Find Full Text PDF

The significance of the slow coronary flow phenomenon (SCFph), as visualized in patients (pts) with angiographically normal coronary arteries, is controversial. Absolute coronary flow reserve (CFR) in the left anterior descending coronary artery (LAD), non-invasively assessed by a transthoracic color-guided pulsed-wave Doppler (E-Doppler TTE), is a reliable parameter to assess coronary microcirculatory dysfunction (CMD). Mild and angiographically hidden epicardial atherosclerosis (Hath), as visualized by intracoronary ultrasound (IVUS), which could be the clue to atherosclerotic coronary microvascular involvement, has never been investigated together with CFR in patients.

View Article and Find Full Text PDF

Wellens' Syndrome from COVID-19 Infection Assessed by Enhanced Transthoracic Coronary Echo Doppler: A Case Report.

Diagnostics (Basel)

March 2022

Institute of Cardiovascular Disease, Department of Emergency and Organ Transplantations, University of Bari "Aldo Moro", 70124 Bari, Italy.

Wellens' syndrome (WS) is a preinfarction state caused by a sub-occlusion of the proximal left anterior descending coronary artery (LAD). In this case report, for the first time, we describe how this syndrome can be caused by COVID-19 infection and, most importantly, that it can be assessed bedside by enhanced transthoracic coronary echo Doppler (E-Doppler TTE). This seasoned technique allows blood flow Doppler to be recorded in the coronaries and at the stenosis site but has never been tested in an acute setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!