A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and Efficacy of the Sientra Silicone Gel Round and Shaped Breast Implants: 6-Year Results of the U.S. Postapproval Study. | LitMetric

Background: After approval of Sientra silicone gel breast implants in March of 2012, the U.S. Food and Drug Administration required completion of a 10-year U.S. postapproval study. The authors present results from the first 6 years of this study.

Methods: An ongoing, open-label, prospective, multicenter study is being conducted to evaluate the long-term clinical performance of Sientra implants in patients undergoing breast augmentation, reconstruction, and revision in the postmarket environment. Enrollment of 5197 patients (10,327 implants) was completed on March 6, 2015 (4046 primary augmentation, 895 revision-augmentation, 149 primary reconstruction, and 107 revision-reconstruction). Analyses were conducted at year 6 (database lock: January 24, 2022).

Results: Across all cohorts who received an implant, the Kaplan-Meier risk of investigator-reported Baker grade III/IV capsular contracture was 4.1% (3.9% with submuscular placement and 6.75%with subglandular placement), the risk of reoperation was 11.6%, and the risk of implant removal was 7.8% (5.9% with implant replacement and 2.0% without replacement). The primary reason (>50%) for reoperation was aesthetic (eg, style/size change). The Kaplan-Meier risk of rupture, calculated for patients who underwent explantation or MRI for rupture evaluation, was 5.8%. Overall, 82.6% of patients were highly satisfied/happy with their implant. No cases of breast implant-associated anaplastic large cell lymphoma were reported.

Conclusion: Six-year results of the postapproval study were consistent with the 10-year core study and provide additional evidence in a large data set supporting the comprehensive safety and effectiveness profile of the Sientra implants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11195925PMC
http://dx.doi.org/10.1097/PRS.0000000000010953DOI Listing

Publication Analysis

Top Keywords

postapproval study
12
sientra silicone
8
silicone gel
8
breast implants
8
sientra implants
8
kaplan-meier risk
8
implants
5
study
5
safety efficacy
4
sientra
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!