The present study aimed to correlate the various electrophysiological tests of ECAP, EABR and ESRT with programming parameters. If there is a correlation between them, fitting formulae to be derived to predict programming parameters. Further this fitting formula was validated on a clinical population. 22 children between age range of 5-12 years using MED-EL implant participated study. Electrophysiological tests of Electrically evoked compound Action Potential (ECAP), Electrical Evoked Stapedial Reflex Threshold (ESRT) and Electrically Evoked Auditory Brain Stem Responses (EABR) were measured on electrodes no 1,4, 8, and 11. Based on Pearson correlation analysis, there was a moderate correlation observed between each of electrophysiological tests with MCL level. Fitting formulae of ECAP with either ESRT or EABR were found to be accurately predict the MCL level. These fitting formulae were clinically validated on 6 children using Sonata implant with OPUS 2 processor. Two new programs with MCL were predicted using combination of ECAP with EABR and ECAP with ESRT as parameters in the fitting formulae. These programs were given to the participants to use for two weeks. Predicted MCLs were found to slightly higher (about 2qu to 5qu) than original MCL level. Reliability analysis indicated that the formulae predicted MCL with good accuracy. Speech perception and sound field thresholds were measured in the participants' Everyday program and two predicted programs. When ECAP & EABR were the parameters, the predicted program had improved audibility as reflected in sound field thresholds as compared to those obtained with other two programs. Based on Freidman test, the results indicated that significantly lower thresholds were found for both ECAP & EABR, or ECAP & ESRT based programs when compared to Everyday program. However, speech perception scores were not significantly different among the program as per Freidman test. Thus, both the fitting models were clinically validated. The findings imply that it is not always advisable to run all three electrophysiological testing to predict the MCL levels in clinical population. It would save lot of time to run just two tests to predict the MCL in difficult to test population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijporl.2023.111696 | DOI Listing |
Audiol Res
June 2024
MED-EL GmbH, Riyadh 52091, Saudi Arabia.
(1) Background: Cochlear implants (CIs) are widely applied to recover audition for patients with severe degrees of or total hearing loss. Electrical stimulation using the electrically evoked ABR (E-ABR) can be recorded in CI recipients through the device. This work was designed to study E-ABR recorded individually from different channels located at the apical, middle, and basal cochlear regions in comparison to their simultaneous separated or adjacent combined recordings.
View Article and Find Full Text PDFAm J Audiol
September 2024
Audiology and Speech-Language Pathology Program, University of Ottawa, Ontario, Canada.
Purpose: Magnetic resonance imaging (MRI), electric compound action potential (eCAP), and electric auditory brainstem response (eABR) are among the routine assessments performed before and/or after cochlear implantation. The objective of this review was to systematically summarize and critically appraise existing evidence of the prognostic value of eCAP, eABR, and MRI for predicting post-cochlear implant (CI) speech perception outcomes in children, with a particular focus on the lesion site.
Method: The present systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 statement.
J Clin Med
November 2023
Departement of Otorhinolarygology, Head and Neck Surgery, University Medicine Greifswald, 17475 Greifswald, Germany.
By using outcome prediction scores, it is possible to distinguish between good and poor performers with cochlear implants (CI) after CI implantation. The reasons for poor performance, despite good basic conditions, can be manifold. On the one hand, the postoperative fitting may be inadequate; on the other, neurophysiological disease processes may impair speech understanding with a CI.
View Article and Find Full Text PDFInt J Pediatr Otorhinolaryngol
September 2023
Department of Audiology, All India Institute of Speech and Hearing, Mysore, India. Electronic address:
The present study aimed to correlate the various electrophysiological tests of ECAP, EABR and ESRT with programming parameters. If there is a correlation between them, fitting formulae to be derived to predict programming parameters. Further this fitting formula was validated on a clinical population.
View Article and Find Full Text PDFCochlear Implants Int
September 2023
Department of ENT at Unfallkrankenhaus Berlin, Charité Medical School, University of Berlin, Berlin, Germany.
Upper current limits (C-levels) are sometimes extremely increased over time since this procedure can enhance speech perception. It should be clarified if a larger amount of electrical stimulation is tolerated by the remaining peripheral and central auditory pathway. An animal electrode array was inserted in mechanically deafened guinea pigs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!