Although transcatheter aortic valve implantation (TAVI) is considered a superior option to surgery in patients with small aortic annulus (SAA), it is not clear which type of transcatheter heart valve (THV) has better results in terms of echocardiographic hemodynamics and clinical outcomes. A random-effects meta-analysis was performed comparing balloon-expandable valves (BEVs) and self-expanding valves (SEVs) in patients with SAA who underwent TAVI regarding their impact on hemodynamic and clinical outcomes at short- and midterm follow-up. Relative risk (RR) and mean difference (MD) with 95% confidence interval (95% CI) were measured for the outcomes, as appropriate. Subgroup analyses were performed based on the generation type of devices and study designs. A total of 16 articles comprising 1 randomized trial, 3 propensity-matched studies, and 12 observational studies including 4,341 patients (1,967 in BEV and 2,374 in the SEV group) with SAA were included. The implantation of BEVs correlated with a lower indexed effective orifice area (MD -0.19 [-0.25 to -0.13]) and higher transvalvular mean pressure gradient (MD 3.91, 95% CI 2.96 to 4.87). Compared with SEVs, BEVs had increased risk of prosthesis-patient mismatch (PPM; RR 2.09, 95% CI 1.79 to 2.45) and severe PPM (RR 2.16, 95% CI 1.48 to 3.15). However, BEV had lower moderate and severe paravalvular leak (RR 0.45, 95% CI 0.29 to 0.69), risk of stroke (RR 0.57, 95% CI 0.42 to 0.76), and permanent pacemaker implantation (RR 0.63, 95% CI 0.44 to 0.91). The 1-year all-cause mortality (RR 1.13, 95% CI 0.86 to 1.49) and cardiac-related mortality (RR 1.53, 95% CI 0.24 to 9.81) were not different between the 2 groups. In conclusion, SEVs were associated with larger indexed effective orifice area and lower PPM but higher paravalvular leak. In contrast, patients with SEVs were more likely to develop stroke and required permanent pacemaker implantation. Both THVs did not show difference in terms of early and midterm all-cause and cardiac mortality. Because both types of THVs show similar results regarding mortality data, hemodynamics should be among the factors considered in decision making for patients with SAA who underwent TAVI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2023.07.100DOI Listing

Publication Analysis

Top Keywords

95%
10
transcatheter aortic
8
aortic valve
8
valve implantation
8
patients small
8
small aortic
8
aortic annulus
8
clinical outcomes
8
patients saa
8
saa underwent
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!