A novel analytical solution of non-linear chromatography in case of parabolic isotherm for frontal analysis was obtained by combination of Cole-Hopf and Laplace transform. It was used for simulation of strontium capturing on chromatographic column with aim to improve quantitative determination of low-level Sr activities. From the experimentally determined breakthrough curves, the retention factor and the number of theoretical plates were calculated using the Glueckauf and Wenzel relations and by fitting the breakthrough curves for the linear isotherm using MatLab. These were used to simulate the breakthrough curves using a parabolic isotherm solution where the non-linear term of the isotherm was taken as a small negative deviation of the retention factor. On the base of theoretical prediction and experimental data, procedure for automated capturing of strontium on chromatographic column with specific dimension and off line "on-column" Cherenkov detection on commercial ultra low-level liquid scintillation counter was developed. It was shown that analytical solution for parabolic isotherm in comparison with solution for linear isotherm gives better prediction of mass of captured Sr on column filled with small amount of Sr resin and SuperLig®620 in case of elevated Sr concentration, even when non-linear effect is not obvious. The solution also makes it possible to predict the mass of resin required for strontium isolation at 100% yield under given conditions. Considering the limited dimensions of the column, and consequently small mass of the resin in them, it resulted in the low efficiency of the columns, which, however, did not affect the yield in real conditions of isolation. The results have shown that the yields achieved after isolation on SuperLig®620 from real samples are 100%. In addition, it is shown that captured Sr can be detected through Y ingrowth, on column filled with strontium specific resin, with Cherenkov detection efficiency of at least 50%. The efficiency may be enhanced to 60%, depending on parameters which can affect detection efficiency change (type of column, resin type, surrounding solution, etc.). The developed procedures enable quantitative determination of Sr in natural water samples with MDAC below 12 mBq l and solid (soil and vegetation) samples with MDAC below 6 Bq kg within 2-3 days. The proposed solution may easily be implemented in radiochemical laboratories where this type of analysis is routinely done within environmental monitoring or other purposes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2023.464276 | DOI Listing |
Proc SPIE Int Soc Opt Eng
February 2024
Radiation Monitoring Devices, Inc., 44 Hunt St., Watertown, MA, USA 02472- 4624.
Development of new scintillator materials is a continuous effort, which recently has been focused on materials with higher stopping power. Higher stopping power can be achieved if the compositions include elements such as Tl (Z=81) or Lu (Z=71), as the compounds gain higher densities and effective atomic numbers. In context of medical imaging this translates into high detection efficiency (count rates), therefore, better image quality (statistics, thinner films) or lower irradiation doses to patients in addition to lowering of cost.
View Article and Find Full Text PDFMicrosc Microanal
November 2024
Strategic Technology Research Institute, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong, Daejeon 34113, Republic of Korea.
Reflection electron energy loss spectroscopy (REELS) has played a pivotal role in allowing researchers to explore the characteristics of various bulk materials. This study presents results for the low-loss region of REELS with a new cylindrical lens spectrometer integrated into a low-voltage scanning electron microscope. The operational principles and implementation of the spectrometer are explained through comparisons between electron optical simulations and experimental results.
View Article and Find Full Text PDFVortex free-electron radiation has attracted considerable interest because of its promising potential for applications in communication, high-density radiation sources, and particle detection. Here, we reveal angular momentum modulation of vortex Cherenkov radiation using subwavelength silicon waveguides. The topological charge of vortex radiation field can be controlled by the position parameters of two electron beams based on the rotational symmetry.
View Article and Find Full Text PDFBiomed Phys Eng Express
November 2024
Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI, United States of America.
. To develop a robust method for non-contact surface dosimetry during Total Body Irradiation (TBI) that uses an optimally paired choice of scintillator material with camera photocathode and can work insensitively to the normal ambient room lighting conditions (∼500 Lux)..
View Article and Find Full Text PDFArXiv
October 2024
Department of Biomedical Engineering, University of California, Davis, USA.
Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF) information for each pair of 511-keV annihilation photons improves effective sensitivity but requires high timing resolution. Hybrid materials that emit both scintillation and Cherenkov photons, such as bismuth germanate (BGO), recently offer the potential for more precise timing information from Cherenkov photons while maintaining adequate energy resolution from scintillation photons.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!