Addendum.

Hist Psychol

Published: August 2023

In the last issue of this journal, Ben Harris authored a research note on Margaret Floy Washburn and her cats (see record 2023-67784-001). What was not included with that piece was an image Washburn's bookplate, which shows an image of a cat (quite possibly a likeness of her most acclaimed cat, "Hiram") with an accompanying Biblical verse in Greek, taken from 1 Thessalonians 5:21, which translated reads as "Test all things; hold fast what is good (NKJV)." It is reproduced in this article. (PsycInfo Database Record (c) 2023 APA, all rights reserved).

Download full-text PDF

Source
http://dx.doi.org/10.1037/h0101919DOI Listing

Publication Analysis

Top Keywords

addendum issue
4
issue journal
4
journal ben
4
ben harris
4
harris authored
4
authored note
4
note margaret
4
margaret floy
4
floy washburn
4
washburn cats
4

Similar Publications

Article Synopsis
  • - The study aimed to examine how COVID-19 data was collected and reported in Malawi, focusing on healthcare workers' perceptions of the case-based surveillance forms and identifying factors that impacted data quality.
  • - Interviews with 75 healthcare professionals revealed that issues with form design and case definitions were significant contributors to data quality problems, alongside concerns about data collection processes and insufficient training.
  • - The findings emphasize the need to improve the design of data collection forms to reduce gaps and errors, indicating that better form design is crucial for the effective capture of accurate surveillance data in future efforts.
View Article and Find Full Text PDF

A critical prelude to any community odor assessment should be the prioritization of specific chemical odorants that are most responsible for targeted downwind odors. Unfortunately, and historically, this is a step that has often been bypassed or overlooked. However, correct understanding of the specific impactful volatile organic compounds (VOCs) can inform the follow-on sampling, analytical, and remediation strategies that are most appropriate and efficient, based upon the chemistry behind the issue.

View Article and Find Full Text PDF

Industry representatives on the ICH S1B(R1) Expert Working Group (EWG) worked closely with colleagues from the Drug Regulatory Authorities to develop an addendum to the ICH S1B guideline on carcinogenicity studies that allows for a weight-of-evidence (WoE) carcinogenicity assessment in some cases, rather than conducting a 2-year rat carcinogenicity study. A subgroup of the EWG composed of regulators have published in this issue a detailed analysis of the Prospective Evaluation Study (PES) conducted under the auspices of the ICH S1B(R1) EWG. Based on the experience gained through the Prospective Evaluation Study (PES) process, industry members of the EWG have prepared the following commentary to aid sponsors in assessing the standard WoE factors, considering how novel investigative approaches may be used to support a WoE assessment, and preparing appropriate documentation of the WoE assessment for presentation to regulatory authorities.

View Article and Find Full Text PDF
Article Synopsis
  • The DNA damage response (DDR) is a crucial cellular mechanism that helps cells deal with stress, particularly during cancer development, and operates in an antagonistic pleiotropy manner.
  • The DDR process requires a lot of energy, suggesting a potential relationship with autophagy, which helps provide energy while responding to stress.
  • The study explores whether autophagy activation is solely influenced by DDR or if they interact in a similar antagonistic way throughout the different stages of cancer development, based on previous research findings.
View Article and Find Full Text PDF

Monte Carlo evaluation of uncertainties in photon and electron TG-51 absorbed dose calibration.

J Appl Clin Med Phys

July 2024

Department of Radiation Oncology, William Beaumont University Hospital, Corewell Health, Royal Oak, Michigan, USA.

Purpose: The accuracy of dose delivery to all patients treated with medical linacs depends on the accuracy of beam calibration. Dose delivery cannot be any more accurate than this. Given the importance of this, it seems worthwhile taking another look at the expected uncertainty in TG-51 photon dose calibration and a first look at electron calibration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!