The objective of this study is to present a credibility assessment of finite element modelling of self-expanding nickel-titanium (Ni-Ti) stents through verification and validation (VV) activities, as set out in the ASME VV-40 standard. As part of the study, the role of calculation verification, model input sensitivity, and model validation is examined across three different application contexts (radial compression, stent deployment in a vessel, fatigue estimation). A commercially available self-expanding Ni-Ti stent was modelled, and calculation verification activities addressed the effects of mesh density, element integration and stable time increment on different quantities of interests, for each context of use considered. Sensitivity analysis of the geometrical and material input parameters and validation of deployment configuration with in vitro comparators were investigated. Results showed similar trends for global and local outputs across the contexts of use in response to the selection of discretization parameters, although with varying sensitivities. Mesh discretisation showed substantial variability for less than 4 × 4 element density across the strut cross-section in radial compression and deployment cases, while a finer grid was deemed necessary in fatigue estimation for reliable predictions of strain/stress. Element formulation also led to substantial variation depending on the chosen integration options. Furthermore, for explicit analyses, model results were highly sensitive to the chosen target time increment (e.g., mass scaling parameters), irrespective of whether quasistatic conditions were ensured (ratios of kinetic and internal energies below 5%). The higher variability was found for fatigue life simulation, with the estimation of fatigue safety factor varying up to an order of magnitude depending on the selection of discretization parameters. Model input sensitivity analysis highlighted that the predictions of outputs such as radial force and stresses showed relatively low sensitivity to Ni-Ti material parameters, which suggests that the calibration approaches used in the literature to date appear reasonable, but a higher sensitivity to stent geometry, namely strut thickness and width, was found. In contrast, the prediction of vessel diameter following deployment was least sensitive to numerical parameters, and its validation with in vitro comparators offered a simple and accurate (error ~ 1-2%) method when predicting diameter gain, and lumen area, provided that the material of the vessel is appropriately characterized and modelled.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10411813 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0283492 | PLOS |
Nanotechnology
January 2025
Electronic Sci.&Eng., Xi'an Jiaotong University, 28 Xianning West Road,Beilin District, Xi 'an, Shaanxi Province, China, Xi'an, 710049, CHINA.
The accurate estimation of the temperature distribution of the GaN based power devices and optimization of the device structure is of great significance to possibly solve the self-heating problem, which hinders the further enhancement of the device performances. We present here the operando temperature measurement with high spatial resolution using Raman spectroscopy of AlGaN/GaN high electron mobility transistors (HEMTs) with different device structures and explore the optimization of the device thermal design accordingly. The lateral and depth temperature distributions of the single-finger HEMT were characterized.
View Article and Find Full Text PDFJ Phys Chem A
January 2025
Department of Chemistry, Faculty of Science, University of Helsinki, P.O. Box 55, A.I. Virtanens Plats 1, University of Helsinki FI-00014, Finland.
We point out that although a litany of studies have been published on atoms in hard-wall confinement, they have either not been systematic, having only looked at select atoms and/or select electron configurations, or they have not used robust numerical methods. To remedy the situation, we perform in this work a methodical study of atoms in hard-wall confinement with the HelFEM program, which employs the finite element method that trivially implements the hard-wall potential, guarantees variational results, and allows for easily finding the numerically exact solution. Our fully numerical calculations are based on nonrelativistic density functional theory and spherically averaged densities.
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of Biomedical Engineering and Chemical Engineering, University of Texas at San Antonio, San Antonio, TX, United States.
Introduction: Research on head impact characteristics, especially position-specific investigations in football, has predominantly focused on collegiate and professional levels, leaving a gap in understanding the risks faced by high school players. Therefore, this study aimed to investigate the effect of three factors-player position, impact location, and impact type-on the frequency, severity, and characteristics of impacts in high school American football. Additionally, we examined whether and how player position influences the distribution of impact locations and types.
View Article and Find Full Text PDFAdvancements in plasmonic sensing require simultaneous detection capability that ensures large-scale detection with reduced losses. In this work, we propose a new solid-core fiber-based refractive index (RI) sensor with an ultra-broad detection range. The proposed fiber consists of a relatively simple single-ring cladding with six circular tubes in which the light is guided in the core based on the inhibited-coupling (IC) mechanism.
View Article and Find Full Text PDFFilm-coupled plasmonic resonators offer efficient platforms for light enhancement due to the excitation of gap surface plasmons (GSPs) at metal-insulator-metal interfaces, where electromagnetic energy is stored within the spacer. In applications like biosensing and spontaneous emission control, spatial overlap between the target molecule and plasmonic hotspots is essential. Here, we propose utilizing the controllable, efficient light enhancement capabilities of a specifically designed GSP disk resonator for biosensing and spontaneous emission enhancement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!