Diagnostic accuracy of Tc-HYNIC-TOC SPECT/CT for detecting osteomalacia-associated tumors.

Front Oncol

Department of Nuclear Medicine, Henan Key Laboratory of Novel Molecular Probes and Clinical Translation in Nuclear Medicine, Henan Provincial People's Hospital; Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou, China.

Published: July 2023

Objectives: Tumor-induced osteomalacia (TIO) is a rare acquired paraneoplastic disorder characterized by hypophosphatemia resulting from tumor-secreted fibroblast growth factor-23 (FGF23). Surgical resection of the culprit TIO is the first choice of treatment. However, TIO is difficult to detect with conventional diagnostic tools due to its small size and variable location in the body. Somatostatin receptor scintigraphy (SSR) has recently emerged as a functional molecular imaging choice for TIO detection and localization. This research was undertaken to evaluate the efficacy of Tc-labeled hydrazinonicotinyl-Tyr3-octreotide (Tc-HYNIC-TOC) SPECT/CT in detecting TIO.

Methods: Tc-HYNIC-TOC SPECT/CT and the available clinical data of 25 patients with suspected TIO were analyzed retrospectively. The Tc-HYNIC-TOC SPECT/CT findings were compared with the post-surgical pathology diagnosis and clinical follow-up results.

Results: Using Tc-HYNIC-TOC SPECT/CT, suspicious tumors were found in 18 of the 25 patients, and 15 of them underwent surgical resection. The post-operative pathology confirmed a TIO in those 13 patients whose symptoms and biochemical anomalies gradually resolved after the surgery. The remaining five patients were finally considered false positives. Moreover, the Tc-HYNIC-TOC SPECT/CT results were negative in seven patients, with six patients being true negative (4 patients were diagnosed with acquired Fanconi syndrome and 2 patients responded well to conservative therapy) and one being false negative. Therefore, the sensitivity and specificity values of Tc-HYNIC-TOC SPECT/CT in the evaluation of TIO were 92.9% (13/14) and 54.5% (6/11), respectively. The overall accuracy of Tc-HYNIC-TOC SPECT/CT for detecting TIO was 76.0% (19/25).

Conclusions: The Tc-HYNIC-TOC SPECT/CT is an accurate imaging modality for locating culprit tumors in TIO.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10405922PMC
http://dx.doi.org/10.3389/fonc.2023.1228575DOI Listing

Publication Analysis

Top Keywords

tc-hynic-toc spect/ct
36
spect/ct detecting
12
tc-hynic-toc
9
spect/ct
9
tio
9
accuracy tc-hynic-toc
8
surgical resection
8
patients
8
negative patients
8
diagnostic accuracy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!