Colorimetric sensor based on biogenic nanomaterials for high sensitive detection of hydrogen peroxide and multi-metals.

Chemosphere

Sen Research Group, Biochemistry Department, Faculty of Arts and Science, Dumlupinar University, Evliya Celebi Campus, 43100, Kutahya, Turkiye; SRG Incorporated Company, Kutahya Design & Technopole, Calca OSB Neighbourhood, 43100 Kutahya, Turkiye. Electronic address:

Published: October 2023

Hydrogen peroxide (HO) and heavy metals, which are among the wastes of the industrial sector, become a threat to living things and the environment above certain concentrations. Therefore, the detection of both HO and heavy metals with simple, low-cost, and fast analytical methods has gained great importance. The use of nanoparticles in colorimetric sensor technology for the detection of these analytes provides great advantages. In recent years, green synthesis of nanomaterials with products that can be considered biowaste is among the popular topics. In this study, silver/silver chloride nanoparticles (Ag@AgCl NPs) were synthesized using the green synthesis method as an eco-friendly and cheap method, the green algae extract was used as a reducing agent. The characterization of Ag@AgCl nanoparticles and green algae extract was carried out with several techniques such as Transmission Electron Microscopy (TEM), UV-Visible spectrometry (UV-Vis), Fourier-transform infrared spectroscopy (FTIR), and X-ray diffraction patterns (XRD) methods were used for characterization. According to TEM analysis, the Ag@AgCl NPs typically spherical in form and range in size from 4 to 10 nm, and UV-vis showed the formation of surface plasmon resonance (SPR) of the Ag@AgCl between 400 and 450 nm. In addition, its activity as a colorimetric sensor for hydrogen peroxide (HO) and multi-metal detection was evaluated. Interestingly, Ag/AgCl NPs caused different color formations for 3 metals simultaneously in the sensor study for heavy metal detection, and Fe, Cu, and Cr ions were detected. The R values for HO, Fe, Cu, and Cr were 0.9360, 0.9961, 0.9787, and 0.9625 the limit of detection (LOD) was 43.75, 1.69, 3.18, and 5.05 ppb (ng/mL), respectively. It was determined that Ag@AgCl NPs have the potential to be used as a colorimetric sensor for the detection of HO and heavy metals from wastewater.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2023.139702DOI Listing

Publication Analysis

Top Keywords

colorimetric sensor
16
hydrogen peroxide
12
heavy metals
12
ag@agcl nps
12
detection heavy
8
green synthesis
8
green algae
8
algae extract
8
detection
7
ag@agcl
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!