A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of alternate material Onyx™ for total knee arthroplasty instrumentation sets. | LitMetric

Context: A 25-pound weight limit is currently set on containerized instrumentation sets by the Association of periOperative Registered Nurses (AORN) and the Association for the Advancement of Medical Instrumentation (AAMI), in order to reduce strain on the staff and ensure that the sets are not too crowded in order to preserve sterilization and drying of the instruments. This is pushing companies to reduce the weight and number of instrumentation sets for the operating room. One solution has been to explore the viability of new, lighter materials such as Onyx.

Objectives: The goal of this study is to evaluate the novel material Onyx as a viable material utilized in reusable total knee arthroplasty (TKA) instrumentation sets utilizing traditional steam sterilization as the sterilization method.

Methods: Mechanical and biocompatibility tests according to the American Society for Testing Materials (ASTM) and International Organization for Standardization (ISO) 10,993 were run to evaluate the Onyx Material to see if it would be a viable alternative to the stainless and martensitic steel that is currently being utilized.

Results: Gross warping and cracking after 10 rounds of sterilization was observed. This was qualitatively worse in the Onyx without a carbon fiber component. The Onyx material did not meet biocompatibility standards for its application.

Conclusions: Onyx was determined to not be a viable material for TKA instruments regarding multiple high-pressure and -temperature sterilizations and cytotoxic cell testing.

Download full-text PDF

Source
http://dx.doi.org/10.1515/jom-2023-0116DOI Listing

Publication Analysis

Top Keywords

instrumentation sets
16
total knee
8
knee arthroplasty
8
viable material
8
onyx material
8
material
6
instrumentation
5
sets
5
onyx
5
analysis alternate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!