Objective: To develop an evidence-based protocol for audiology-based, cochlear implant (CI) programming in the first year after activation.
Study Design: Retrospective case review.
Setting: CI program at a tertiary medical center.
Patients: One-hundred seventy-one patients (178 ears; mean age at implantation, 62.3 yr; 44.4% female) implanted between 2016 and 2021 with postlingual onset of deafness and no history of CI revision surgery. Patients included here had confirmed CI programming optimization based on CI-aided thresholds in the 20- to 30-dB-HL range as well as upper stimulation levels guided by electrically evoked stapedial reflex thresholds.
Main Outcome Measures: Consonant-nucleus-consonant monosyllabic word recognition scores in the CI-alone and bilateral best-aided conditions at five time points: preoperative evaluation, and 1, 3, 6, and 12 months after activation.
Results: For both the CI-alone and bilateral best-aided conditions, consonant-nucleus-consonant word recognition significantly improved from preoperative evaluation to all postactivation time points. For the CI-alone condition, no significant differences were observed between 3 and 6 months, or from 6 to 12 months after activation. In contrast, for the bilateral best-aided condition, significant differences were observed between 1 and 3 months, and 3 and 6 months, but no difference in scores between 6 and 12 months.
Conclusions: Based on the current data set and associated analyses, CI centers programming adult patients could eliminate either the 3- or 6-month visit from their clinical follow-up schedule if patient mapping of lower and upper stimulation levels is validated via CI-aided audiometric thresholds and electrically evoked stapedial reflex thresholds, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAO.0000000000003968 | DOI Listing |
Clin Linguist Phon
January 2025
BKV, Linköping University, Linköping, Sweden.
Gestures are essential in early language development. We investigate the use of gestures in children with cochlear implants (CIs), with a particular focus on deictic, iconic, and conventional gestures. The aim is to understand how the use of gestures in everyday interactions relates to age, vocabulary testing results, and language development reported by parents.
View Article and Find Full Text PDFCureus
December 2024
Department of Otolaryngology - Head and Neck Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, JPN.
Objective We aimed to highlight problems faced by parents of infants diagnosed with hearing impairment upon newborn hearing screening (NHS) and to suggest how support might be improved. Methods We distributed a questionnaire to explore difficulties encountered by parents when seeking support, whether they were satisfied with the support, and their unmet needs. We enrolled 101 parents of infants with hearing impairments diagnosed upon NHS (hearing levels: 7.
View Article and Find Full Text PDFActa Otolaryngol
January 2025
Department of Audiology and Prevention of Communication Disorders, All India Institute of Speech and Hearing, Mysuru, Karnataka, India.
Background: Although Cochlear implantation (CI) is effective in restoring hearing for children with severe-to-profound sensorineural hearing loss, it may influence the middle ear mechanics, potentially causing an air-bone gap and altering middle ear stiffness, which is not detected by traditional 226 Hz tympanometry.
Aims/objectives: To investigate the effect of mastoidectomy posterior tympanotomy (MPTA) on wideband absorbance (WBA) in children with CI.
Materials And Methods: The study included 20 normal-hearing children (normal group) and 10 children with CIs who underwent MPTA (CI-MPTA group), aged 3-10 years.
Ear Hear
January 2025
Department of Otorhinolaryngology and Head and Neck Surgery, Radboud University Medical Centre, Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands.
Objectives: Real-time monitoring of cochlear function to predict the loss of residual hearing after cochlear implantation is now possible. Current approaches monitor the cochlear microphonic (CM) during implantation from the electrode at the tip of the implant. A drop in CM response of >30% is associated with poorer hearing outcomes.
View Article and Find Full Text PDFHNO
January 2025
Deutsches Hörzentrum der Medizinischen Hochschule Hannover, Karl-Wiechert-Allee 3, 30625, Hannover, Deutschland.
Treatment of patients with severe hearing loss or deafness using cochlear implants (CI) is nowadays clinical routine. In the Hannover Medical School alone, more than 500 patients are treated with CI annually, meaning that the pool of patients with CI increases significantly each year. Worldwide, there are over 1 million patients with a CI system; in Germany the figure is estimated at over 60,000.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!