Role of Static and Dynamic Ocular Biometrics Measured in the Dark and Light as Risk Factors for Angle Closure Progression.

Am J Ophthalmol

State Key Laboratory of Ophthalmology (Y.J., Y.J., M.H.), Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, People's Republic of China.

Published: December 2023

Purpose: To assess the role of static and dynamic ocular biometric parameters measured in the dark and light for predicting progression of primary angle closure suspect (PACS) to primary angle closure (PAC).

Design: Retrospective cohort study using prospective randomized controlled trial data from untreated, control eyes.

Methods: Zhongshan Angle Closure Prevention Trial subjects underwent anterior segment optical coherence tomography (AS-OCT) imaging in the dark and light. Static biometric parameters were measured, consisting of angle, iris, lens, and anterior chamber parameters. Dynamic change parameters were calculated by subtracting light measurements from dark measurements. Cox proportional hazards regression models were developed to assess risk factors for PACD progression.

Results: A total of 861 eyes of 861 participants were analyzed (36 progressors). On univariable analysis, TISA500 measurements in the light and dark were associated with progression (P < .001), whereas dynamic change parameters were not (P ≥ .08). In the primary multivariable model, older age (hazard ratio [HR] = 1.09 per year), higher intraocular pressure (IOP) (HR = 1.13 per mm Hg), and smaller TISA500 in the light (HR = 1.28 per 0.01 mm) were significantly associated with greater risk of progression (P ≤ .04). Dark TISA500 had similar significance (HR = 1.28, P = .002) when replacing light TISA500. Risk of progression was more predictive among eyes in the lowest quartile of light TISA500 measurements (HR = 4.56, P < .001) compared to dark measurements (HR = 2.89, P = .003).

Conclusion: Static parameters measured in the light are as predictive, and possibly more so, of angle closure progression as those measured in the dark. Ocular biometrics measured under light and dark conditions may provide additional information for risk-stratifying patients for angle closure progression.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10840898PMC
http://dx.doi.org/10.1016/j.ajo.2023.07.032DOI Listing

Publication Analysis

Top Keywords

angle closure
24
measured dark
12
dark light
12
closure progression
12
parameters measured
12
light
10
dark
9
role static
8
static dynamic
8
dynamic ocular
8

Similar Publications

Purpose: To evaluate changes in intraocular pressure (IOP) in dominant and contralateral eyes following the dark room prone provocative test (DRPPT) in the study subjects with shallow anterior chamber.

Methods: This was a prospective, single-center, non-randomized controlled trial of 43 subjects (86 eyes) with shallow anterior chamber. The dominant eye was identified using the card-hole method.

View Article and Find Full Text PDF

Purpose: To develop an artificial intelligence algorithm to automatically identify the anterior segment structures and assess multiple parameters of primary angle closure disease (PACD) in ultrasound biomicroscopy (UBM) images.

Design: Development and validation of an artificial intelligence algorithm for UBM images.

Methods: 2339 UBM images from 592 subjects were collected for algorithm development.

View Article and Find Full Text PDF

Objective: To report clinical outcomes of skeletally immature dogs with antebrachial deformities secondary to premature closure of the distal radial physis (PCDRP) treated with angular corrections and distraction osteogenesis using circular external skeletal fixation (CESF).

Study Design: Retrospective multi-institutional case series.

Animals: A total of 12 client-owned dogs with premature distal radial physeal closure.

View Article and Find Full Text PDF

Esophago-jejunal anastomoses fistula could be mortal. Currently there is a wide therapeutic measure ranging from conservative management, endoscopic therapy and surgery. Endoscopic management has been positioned above other strategies due to minimal invasion which improves survival and reduces mortality.

View Article and Find Full Text PDF

Multifunctional dual-layer wound dressings hold significant promise for comprehensive full-thickness wound management by closely mimicking the native skin structure and features. Herein, we employed an innovative approach utilizing electrospinning techniques to develop a dual-layer dressing comprising a microfibrous Ecoflex®-Vanillin (Ex-Vnil) top layer (TL) and a nanofibrous Soluplus®-Insulin-like growth factor-1 (Sol-IGF1) bottom layer (BL). The tensile properties of dual-layer wound dressings were within the standard range for use in skin tissue regeneration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!