Deep learning based parallel imaging (PI) has made great progress in recent years to accelerate MRI. Nevertheless, it still has some limitations: for example, the robustness and flexibility of existing methods are greatly deficient. In this work, we propose a method to explore the k-space domain learning via robust generative modeling for flexible calibrationless PI reconstruction, coined the weighted k-space generative model (WKGM). Specifically, WKGM is a generalized k-space domain model, where the k-space weighting technology and high-dimensional space augmentation design are efficiently incorporated for score-based generative model training, resulting in good and robust reconstructions. In addition, WKGM is flexible and thus can be synergistically combined with various traditional k-space PI models, which can make full use of the correlation between multi-coil data and realize calibrationless PI. Even though our model was trained on only 500 images, experimental results with varying sampling patterns and acceleration factors demonstrate that WKGM can attain state-of-the-art reconstruction results with the well learned k-space generative prior.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.5005DOI Listing

Publication Analysis

Top Keywords

k-space generative
12
generative model
12
weighted k-space
8
parallel imaging
8
k-space domain
8
k-space
7
wkgm
5
generative
5
model
5
wkgm weighted
4

Similar Publications

Application of Deep Learning Accelerated Image Reconstruction in T2-weighted Turbo Spin Echo Imaging of the Brain at 7T.

AJNR Am J Neuroradiol

January 2025

From the Department of Radiology, Mayo Clinic, Jacksonville, FL, USA (Z.L., X.Z., S.T., V.P., E.M.W., V.G., E.H.M.), Department of Radiology, Peking Union Medical College Hospital, Beijing, China (Z.L.), Siemens Medical Solutions USA, Inc., Jacksonville, FL, USA (J.M.), MR Application Predevelopment, Siemens Healthineers AG, Forchheim, Germany (D.N., P.L.), Siemens Healthineers, Princeton, NJ, USA (M.M.), Siemens Medical Solutions USA, Inc., Scottsdale, AZ, USA (H.M.), and Department of Radiology, Mayo Clinic, Scottsdale, AZ, USA (H.M.).

Prolonged imaging times and motion sensitivity at 7T necessitate advancements in image acceleration techniques. This study evaluates a 7T deep-learning (DL)-based image reconstruction using a deep neural network trained on 7T data, applied to T2-weighted turbo spin echo imaging. Raw k-space data from 30 consecutive clinical 7T brain MRI patients was reconstructed using both DL and standard methods.

View Article and Find Full Text PDF

Data on full stationary wave-field measurement of a suspended steel plate punctually loaded.

Data Brief

February 2025

Institut Camille Jordan, UMR-CNRS 5208, École Centrale de Lyon, 36 Avenue Guy de Collongue, 69134, Écully, France.

The dataset presented contains the experimental structural response, in the frequency domain, of a suspended steel plate to a point force excitation. The plate is excited by a mechanical point force generated by a Brüel & kJær shaker with a white noise signal input from 3.125 Hz to 2000 Hz.

View Article and Find Full Text PDF

Objectives: Phosphorus-31 magnetic resonance spectroscopic imaging (P-MRSI) is a non-invasive tool for assessing cellular high-energy metabolism in-vivo. However, its acquisition suffers from a low sensitivity, which necessitates large voxel sizes or multiple averages to achieve an acceptable signal-to-noise ratio (SNR), resulting in long scan times.

Materials And Methods: To overcome these limitations, we propose an acquisition and reconstruction scheme for FID-MRSI sequences.

View Article and Find Full Text PDF

Magnetic Resonance Imaging (MRI) stands out as a notable non-invasive method for medical imaging assessments, widely employed in early medical diagnoses due to its exceptional resolution in portraying soft tissue structures. However, the MRI method faces challenges with its inherently slow acquisition process, stemming from the sequential sampling in k-space and limitations in traversal speed due to physiological and hardware constraints. Compressed Sensing in MRI (CS-MRI) accelerates image acquisition by utilizing greatly under-sampled k-space information.

View Article and Find Full Text PDF

Partition-based k-space synthesis for multi-contrast parallel imaging.

Magn Reson Imaging

December 2024

Department of Electronic Information Engineering, Nanchang University, Nanchang 330031, China. Electronic address:

Purpose: Multi-contrast magnetic resonance imaging is a significant and essential medical imaging technique. However, multi-contrast imaging has longer acquisition time and is easy to cause motion artifacts. In particular, the acquisition time for a T2-weighted image is prolonged due to its longer repetition time (TR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!