Aims: Sodium-glucose cotransporter-2 inhibitors (SGLT2i) decrease mortality and risk of hospitalization in patients with heart failure with reduced ejection fraction (HFrEF). SGLT2i have a natriuretic effect shortly after initiation, followed by a lasting osmotic diuretic effect. We sought to evaluate rates of acute kidney injury (AKI) and therapy discontinuation with SGLT2i initiation in a real-world cohort of HFrEF patients.

Methods And Results: We abstracted data on 200 patients with HFrEF initiated on a SGLT2i in the outpatient setting at the University of Michigan (between 1 July 2016 and 2 July 2022). Our co-primary endpoints were rate of AKI and discontinuation of SGLT2i. A total of 200 patients were included. The majority of patients were male (64%) with a mean left ventricular ejection fraction (LVEF) of 27%. One hundred and four (52%) patients had diabetes mellitus. Most patients exhibited New York Heart Association class II (51.5%) or III (33.5%) symptoms. The majority of patients (54%) were taking an angiotensin-receptor neprilysin inhibitor. The mean daily furosemide equivalent diuretic dose was 93.3 mg. AKI occurred in 22 patients and 18 patients discontinued their SGLT2i. Yeast infection (n = 6), hypotension (n = 5), and AKI (n = 4) were the most common reasons for discontinuation. Using receiver operating characteristic curve analysis, the strongest models for AKI were A1C [area underneath its curve (AUC) = 75.8, empirical confidence interval (ECI) 66.5-83.5]; baseline serum creatinine (SCr) (AUC = 72.0, ECI 65.7-78.7); LVEF (AUC = 67.6, ECI 58.4-75.8); and furosemide equivalent diuretic dose (AUC = 66.0, ECI 57.5-74.6). Similarly, the strongest positive models for SGLT2i discontinuation were A1C (AUC = 81.1, ECI 74.8-87.2); baseline SCr (AUC = 67.4, ECI 58.7-75.5); LVEF (AUC = 68.7, ECI 58.9-76.5); and furosemide equivalent diuretic dose (AUC = 67.2, ECI 58.2-76.0).

Conclusions: A1C was the strongest model of AKI, and SGLT2i discontinuation in HFrEF patients started on SGLT2i. Glucosuria may be related to this effect. Patients with higher baseline SCr on higher doses of loop diuretics may be at greater risk of these outcomes. Future prospective studies will be needed to further evaluate these findings and other models of AKI and SGLT2i discontinuation to guide clinical use of SGLT2 inhibitors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10567673PMC
http://dx.doi.org/10.1002/ehf2.14489DOI Listing

Publication Analysis

Top Keywords

patients
12
furosemide equivalent
12
equivalent diuretic
12
diuretic dose
12
sglt2i discontinuation
12
sglt2i
10
sodium-glucose cotransporter-2
8
heart failure
8
ejection fraction
8
discontinuation sglt2i
8

Similar Publications

Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.

Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.

Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.

View Article and Find Full Text PDF

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

[F]FDG PET/CT versus Dynamic Contrast-Enhanced CT for the diagnosis of solitary pulmonary Nodule: A Head-to-Head comparative Meta-Analysis.

Eur J Radiol

January 2025

Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:

Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.

Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!