This study evaluated the effects of a constant current electrical stimulation (CCES) system and hormonal growth-promoting (HGP) implants on the quality and palatability of the longissimus thoracis et lumborum (LTL) from yearling-finished steers. The experiment used a total of 46 Angus cross steers, which were either non-implanted (n = 20) or implanted with trenbolone acetate and estradiol benzoate (n = 26). The CCES was applied to one side of each carcass during the slaughter process, whereas the other side remained unstimulated. Regardless of the application of HGP implants, the CCES reduced pH at 3 and 72 h post-mortem and shear force at all ageing times (P < 0.05), improved colour at 72 h post-mortem and during the retail display (P < 0.05), increased initial and overall tenderness (P < 0.01), and decreased the amount of perceived connective tissue and the proportion of trained panelists detecting spongy texture (P < 0.05) compared to meat from unstimulated carcass sides. Although CCES increased meat purge losses and reduced moisture content (P < 0.05), this did not affect meat juiciness (P > 0.10). CCES interacted with HGP to prevent increase in drip loss (P > 0.10), increase frequency of panelists detecting bloody/serumy flavour and typical texture, and reduce the proportion of panelists detecting rubbery texture in meat (P < 0.05). Regardless of stimulation treatment, meat from implanted animals had a more pronounced pH decline at 72 h post-mortem (P < 0.05) and a higher proportion of panelists finding no off-flavours (P < 0.05) or bloody/serumy flavour (P < 0.01) than non-implanted cattle. The CCES system tested in this study improved LTL quality and palatability of heavier beef carcasses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.meatsci.2023.109297 | DOI Listing |
Ann Surg Oncol
December 2023
Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Background: Histopathological growth patterns (HGPs) are a prognostic biomarker in colorectal liver metastases (CRLM). Desmoplastic HGP (dHGP) is associated with liver-only recurrence and superior overall survival (OS), while non-dHGP is associated with multi-organ recurrence and inferior OS. This study investigated the predictive value of HGPs for adjuvant hepatic arterial infusion pump (HAIP) chemotherapy in CRLM.
View Article and Find Full Text PDFMeat Sci
November 2023
Lacombe Research and Development Centre, Agriculture and Agri-Food Canada, 6000 C&E Trail, Lacombe, Alberta T4L 1W1, Canada. Electronic address:
This study evaluated the effects of a constant current electrical stimulation (CCES) system and hormonal growth-promoting (HGP) implants on the quality and palatability of the longissimus thoracis et lumborum (LTL) from yearling-finished steers. The experiment used a total of 46 Angus cross steers, which were either non-implanted (n = 20) or implanted with trenbolone acetate and estradiol benzoate (n = 26). The CCES was applied to one side of each carcass during the slaughter process, whereas the other side remained unstimulated.
View Article and Find Full Text PDFMeat Sci
November 2022
School of Environmental and Rural Science, University of New England, Armidale, NSW 2351, Australia.
Carcass value is a complex relationship with varying contributions between eating quality (MSA Index) and lean cut yield (LCY%). Bone-out data from 112 Bos taurus steer carcasses, grain finished for 100 days with a hormonal growth promotant were analyzed. Carcass values were calculated using 1) flat cut prices, 2) cut prices weighted for MSA grades, and 3) cut prices weighted for MSA grades for four high value primals.
View Article and Find Full Text PDFKnee
October 2020
Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), School of Medicine, University of Leeds, Chapel Allerton Hospital, Leeds LS7 4SA, UK; Leeds Teaching Hospitals NHS Trust, Beckett Street, Leeds LS9 7TF, UK.
Background: Unicompartmental knee replacement (UKR) prostheses can use fixed (FB) or mobile bearing (MB) constructs. We compared survivorship and failure modes of both designs.
Methods: The inclusion criteria were studies published between 2005 and 2020 with minimum average follow-up of five years reporting the survival and/or number of revisions of specific designs in medial and lateral UKRs.
Neuroimage
June 2020
Klinik für Neurochirurgie, UniversitätsSpital Zürich und Universität Zürich, Zurich, Switzerland; Zentrum für Neurowissenschaften Zürich, Switzerland. Electronic address:
The amygdala is a central part of networks of brain regions underlying perception and cognition, in particular related to processing of emotionally salient stimuli. Invasive electrophysiological and hemodynamic measurements are commonly used to evaluate functions of the human amygdala, but a comprehensive understanding of their relation is still lacking. Here, we aimed at investigating the link between fast and slow frequency amygdalar oscillations, neuronal firing and hemodynamic responses.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!